Carbolite high temperature clean room drying oven HTCR up to 600 °C
The Carbolite high temperature clean room drying oven HTCR up to 600 °C is a versatile appliance specially developed for demanding applications in laboratories and clean rooms. With a maximum temperature of up to 600 °C, the HTCR is ideal for drying and moisture extraction processes as well as for use in controlled environments. Thanks to its robust design and compliance with strict standards, the HTCR offers reliable performance and high temperature homogeneity. Similar to the Carbolite LHT laboratory high temperature drying oven up to 600 °C, the HTCR is suitable for a wide range of applications.
Technical details and advantages
The Carbolite HTCR drying oven offers a variety of technical features that make it an excellent choice for various applications:
-
Maximum temperature: Up to 600 °C
-
Temperature stability: ±0.5 °C
-
Temperature homogeneity: ±5.0 °C at 250 °C
-
Heating time: Between 60 and 120 minutes depending on the model
-
Internal volume: Available in various sizes from 28 to 1000 liters
-
Air flow: Forced convection
-
Output: Models available with outputs from 1 kW to 15 kW
-
Safety standards: ISO 14644-1 Class 6, BS EN 61010-2-010:2003
The HTCR is available with a wide range of options and accessories, including over-temperature protection, heavy-duty shelves and drawers, digital timers and innovative temperature controls. This adaptability allows the drying cabinet to be tailored to the user's specific requirements.
Certifications and standards
The Carbolite HTCR complies with BS EN 61010-2-010:2003 and ISO 14644-1 Class 6 standards, making it a safe and reliable choice for cleanroom applications. These certifications ensure that the drying oven meets stringent safety and performance standards, which is particularly important in sensitive environments.
Application examples
The Carbolite HTCR drying oven is ideal for a variety of applications in laboratories and cleanrooms:
-
Drying and moisture extraction: ideal for removing moisture from samples and materials.
-
Cleanroom applications: Suitable for use in controlled environments where high air purity is required.
-
Material testing: Used for testing the behavior of materials at high temperatures.
-
Pharmaceutical research: Used in the manufacture and testing of pharmaceutical products.
-
Electronics industry: Drying and curing of electronic components and materials.
FAQs
What is the maximum temperature the HTCR can reach?
The Carbolite HTCR can reach a maximum temperature of up to 600 °C.
What safety standards does the HTCR comply with?
The HTCR complies with BS EN 61010-2-010:2003 and ISO 14644-1 Class 6.
What sizes are available for the HTCR?
The HTCR is available in various sizes with internal volumes from 28 to 1000 liters.
Is the HTCR suitable for cleanroom applications?
Yes, the HTCR is specially designed for use in clean rooms and complies with the relevant standards.
What options and accessories are available for the HTCR?
Available options include over-temperature protection, hard-wearing shelves and pull-outs, digital timers and innovative temperature controllers.
Conclusion
The Carbolite HTCR high temperature cleanroom drying oven up to 600 °C is a versatile and reliable appliance that is ideal for demanding applications in laboratories and cleanrooms. With its high temperature stability, excellent temperature homogeneity and compliance with strict safety standards, the HTCR offers outstanding performance and adaptability. Similar to the Carbolite HTMA gas-tight high temperature drying oven up to 700 °C, the HTCR is an excellent choice for a wide range of applications.
Load max.: |
11 - 50 kg |
Width outside (incubators,...): |
675 mm, 810 mm, 1030 mm, 1115 mm, 1155 mm, 1530 mm |
Width inside (incubators,...): |
305 mm, 455 mm, 610 mm, 800 mm, 1000 mm |
Maximum temperature (heat): |
+ 400 °C, + 500 °C, + 600 °C |
Height outside (incubators,...): |
880 mm, 1010 mm, 1160 mm, 1305 mm, 1310 mm |
Height inside (incubators,...): |
305 mm, 455 mm, 610 mm, 800 mm, 1000 mm |
Interior volume: |
up to 50 l, 51 - 100 l, 201 - 300 l, 501 - 600 l, 901 - 1000 l |
Maximum power: |
1 kW, 2 kW, 3 kW, 4 kW, 4.5 kW, 6 kW, 7.5 kW, 9 kW, 12 kW, 15 kW |
Air convestion (incubators, ...): |
forced |
Suitable for: |
Clean room applications, Drying / moisture extraction |
Cabinet type: |
heating oven, Heating cabinet |
Safety standard: |
ISO 14644-1 Class 6 |
Depth outside (incubators,...): |
885 mm, 1120 mm, 1280 mm, 1450 mm, 1635 mm |
Depth inside (incubators,...): |
305 mm, 455 mm, 610 mm, 800 mm, 1000 mm |
Carbolite
Cleanroom-
Drying Cabinet
HTCR |
Maximum
temperature
(°C) |
Temperature-
Stability
(°C) |
Temperature-
Homogeneity
(°C) |
Heating time
(minutes) |
Recovery-
Time
(minutes) |
Dimensions
Inside
H x W x D
(mm) |
Dimensions
Outside
H x W x D
(mm) |
Perforated sheets
inclusive/
maximum |
Maximum load
per perforated plate/
total
(kg) |
Chamber-
Volume
(litres) |
Maximum
power
(W) |
HTCR 4/28 |
400 |
±0,5 |
±5.0 at 250 °C |
60 |
10 |
305 x 305 x 305 |
880 x 675 x 885
(table-top unit*) |
2/2 |
10/20 |
28 |
1000 |
HTCR 4/95 |
400 |
±0,5 |
±5.0 at 250 °C |
90 |
10 |
455 x 455 x 455 |
1010 x 810 x 1120
(table-top unit*) |
3/4 |
15/30 |
94 |
3000 |
HTCR 4/220 |
400 |
±0,5 |
±5.0 at 250 °C |
75 |
16 |
610 x 610 x 610 |
1160 x 1030 x 1280
(tabletop unit*) |
3/4 |
10/50 |
227 |
4000 |
HTCR 4/500 |
400 |
±0,5 |
±5.0 at 250 °C |
- |
- |
800 x 800 x 800 |
1305 x 1115 x 1450
(floor standing unit*) |
3/5 |
- |
510 |
7500 |
HTCR 4/1000 |
400 |
±0,5 |
±5.0 at 250 °C |
- |
- |
1000 x 1000 x 1000 |
1310 x 1530 x 1635
(floor standing unit*) |
3/5 |
- |
1000 |
12000 |
HTCR 5/28 |
500 |
±0,5 |
±5.0 at 250 °C |
75 |
16 |
305 x 305 x 305 |
880 x 675 x 885
(table-top unit*) |
2/2 |
10/20 |
28 |
2000 |
HTCR 5/95 |
500 |
±0,5 |
±5.0 at 250 °C |
110 |
16 |
455 x 455 x 455 |
1010 x 810 x 1120
(table-top unit*) |
3/4 |
15/30 |
94 |
4500 |
HTCR 5/220 |
500 |
±0,5 |
±5.0 at 250 °C |
105 |
16 |
610 x 610 x 610 |
1160 x 1030 x 1280
(tabletop unit*) |
3/4 |
10/50 |
227 |
6000 |
HTCR 5/500 |
500 |
±0,5 |
±5.0 at 250 °C |
- |
- |
800 x 800 x 800 |
1305 x 1155 x 1450
(floor standing unit*) |
3/5 |
10/20 |
510 |
9000 |
HTCR 5/1000 |
500 |
±0,5 |
±5.0 at 250 °C |
- |
- |
1000 x 1000 x 1000 |
1310 x 1530 x 1635
(floor standing unit*) |
3/5 |
15/30 |
1000 |
15000 |
HTCR 6/28 |
600 |
±0,5 |
±5.0 at 250 °C |
110 |
20 |
305 x 305 x 305 |
880 x 675 x 885
(table-top unit*) |
2/2 |
10/50 |
28 |
2000 |
HTCR 6/95 |
600 |
±0,5 |
±5.0 at 250 °C |
110 |
20 |
455 x 455 x 455 |
1010 x 810 x 1120
(tabletop unit*) |
3/4 |
10/20 |
94 |
4500 |
HTCR 6/220 |
600 |
±0,5 |
±5.0 at 250 °C |
120 |
20 |
610 x 610 x 610 |
1160 x 1030 x 1280
(tabletop unit*) |
3/4 |
15/30 |
227 |
9000 |
HTCR 6/500 |
600 |
±0,5 |
±5.0 at 250 °C |
- |
- |
800 x 800 x 800 |
1305 x 1155 x 1450
(floor standing unit*) |
3/5 |
- |
510 |
12000 |
HTCR 6/1000 |
600 |
±0,5 |
±5.0 at 250 °C |
- |
- |
1000 x 1000 x 1000 |
1310 x 1530 x 1635
(floor standing unit*) |
3/5 |
- |
1000 |
15000 |
Please note:
The minimum working temperature is about 60 °C above room temperature.
Temperature homogeneity measured in empty and closed chamber after a stabilisation phase
Maximum output and heating time with 240 V connection
Outer dimensions with closed door
The zone of homogeneous temperature is smaller than the total volume
* Optional with base
Power supply |
Volt |
Phase |
Amps per phase |
HTCR 5/220 |
220-240 |
1 phase |
19,5 |
|
380-415 |
2 phases + N |
10 |
HTCR 6/220 |
220-240 |
1 phase |
26 |
|
220-240 |
3 phase delta |
15 |
|
380-415 |
3 phases + N |
12,5 |
HTCR 6/95 |
220-240 |
1 phase |
19,5 |
|
380-415 |
2 phases + N |
10 |
All models not listed here in the table can be operated with a 220-240 V, 16 A single-phase connection.
Please specify desired power supply and mains connection when ordering!
Other power connection configurations on request.
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde