BINDER KBF-S 240 constant climate chamber
The BINDER KBF-S 240 constant climate chamber is a versatile all-rounder for the laboratory, which is particularly suitable for cultivating microorganisms, insect or animal cultures as well as for numerous breeding and development processes. Thanks to its precise temperature and humidity control, it is ideal for the precise observation of cell behavior and growth. Compared to similar products such as the BINDER KBWF 240 growth chamber, the KBF-S 240 offers outstanding performance and reliability.
Technical data and functions
The KBF-S 240 offers a wide range of functions that make it an indispensable tool in any laboratory:
-
Cabinet type: constant climate chamber
-
Maximum load: 51 - 100 kg
-
Internal volume: 201 - 300 l
-
Temperature range: 0 to +70 °C
-
Humidity range: 20 to 80 % relative humidity
-
Maximum temperature (heat): +70 °C
-
Lowest temperature (cooling): 0 °C
- Dimensions (inside): 650 mm (width) x 785 mm (height) x 485 mm (depth)
- Dimensions(outside): 925 mm (width) x 1460 mm (height) x 800 mm (depth)
-
Maximum heat output at 40 °C: 300 W
-
Spatial temperature deviation at 40 °C: ±0.3 K
-
Temporal temperature dev iation: ±0.1 K
-
Humidity recovery time after 30 s door opening at 25 °C and 60 % r.h.: 5 minutes
-
Humidity recovery time after 30 s door opening at 40 °C and 75 % r.h.: 11 minutes
-
Appliance fuse: 16 A
-
Rated power: 1.4 kW
-
Rated voltage: 200 to 230 V
-
Mains frequency: 50/60 Hz
-
Phase: 1~
Special features
The KBF-S 240 is equipped with numerous innovative functions that set it apart from other climate chambers:
-
BINDER controller: Simultaneous display of all relevant information
-
Uncomplicated menu navigation: Simple operation and setting
-
Electronic chart recorder: Precise recording of process parameters
-
Graphic display options: Various options for visualizing the data
-
VENTAIR™ air jacket system: Available depending on model
-
Real-time clock: For precise time measurements
-
Standard-compliant hot air sterilization: At 180 °C (DIN 58947)
-
CO2 infrared absorption measuring system: Drift-free and precise
-
ANTI.PLENUM design: Prevents contamination-critical installations
-
Permadry™ system: double tray humidification system with defined condensation location
-
Electronic fault auto-diagnosis system: With visual and acoustic alarm
-
Potential-free changeover contact: For central monitoring
-
Temperature selector monitor: With visual and acoustic temperature alarm
-
Tight-closing inner door: For optimum insulation
-
Ethernet interface: For APT-COM™ DataControlSystem communication software
-
Optional: Multiple stainless steel shelves
-
BINDER test certificate: Guarantees the highest quality and reliability
Application examples
The BINDER KBF-S 240 constant climate chamber is used in various areas, including
-
Laboratories: For the cultivation of microorganisms and cell cultures
-
Medical research: Observation of cell behavior and growth
-
Biotechnology: Development and testing of biological products
-
Pharmaceutical industry: Stability tests and storage of samples
-
Environmental research: simulation of climatic conditions
Certifications and standards
The KBF-S 240 meets the highest standards and norms, including
-
DIN 58947: Standard-compliant hot air sterilization at 180 °C
-
BINDER factory standard: Temperature data according to BINDER factory standard and in accordance with DIN 12880:2007
FAQs
How long does the humidity recovery time take after opening the door?
- At 25 °C and 60 % relative humidity, the humidity recovery time is 5 minutes. At 40 °C and 75 % relative humidity, it is 11 minutes.
What maximum load can the KBF-S 240 carry?
- The KBF-S 240 can carry a maximum load of 100 kg, whereby the maximum load per rack is 30 kg.
What temperature ranges does the KBF-S 240 cover?
- The temperature range of the KBF-S 240 is between 0 and +70 °C.
Conclusion
The BINDER KBF-S 240 constant climate chamber is a highly sophisticated unit that is characterized by its versatility and precision. With its numerous functions and certifications, it is the ideal choice for laboratories and research facilities that require reliable and accurate climate control. Similar products such as the BINDER KBF LQC 240 constant climate chamber also offer excellent performance and could be an interesting alternative.
Load max.: |
51 - 100 kg |
Width outside (incubators,...): |
925 mm |
Width inside (incubators,...): |
650 mm |
Maximum temperature (heat): |
+ 70 °C |
Height outside (incubators,...): |
1460 mm |
Height inside (incubators,...): |
785 mm |
Interior volume: |
201 - 300 l |
Cabinet type: |
constant climate chamber |
Depth outside (incubators,...): |
800 mm |
Depth inside (incubators,...): |
485 mm |
Lowest temperature (cooling): |
0 °C |
Item weight: |
161,00 kg
|
BINDER Constant climate chamber |
KBF-S 240-230V1 |
KBF-S 240UL-240V1 |
Option model |
Standard |
Standard |
Performance Data Temperature |
|
|
Max. heat compensation at 40 °C [W] |
300 |
300 |
Temperature fluctuation [+ K] |
0.1 |
0.1 |
Temperature range [°C] |
0 to 70 |
0 to 70 |
Temperature variation at 40 °C [+ K] |
0.3 |
0.3 |
Performance Data Climate |
|
|
Humidity fluctuation at 25 °C and 60 % RH |
1.5 % RH |
1.5 % RH |
Humidity range [% RH] |
20 to 80 |
20 to 80 |
Humidty recovery time after 30 s door open at 25 °C and 60 % RH [min] |
5 |
5 |
Humidty recovery time after 30 s door open at 40 °C and 75 % RH [min] |
11 |
11 |
Temperature fluctuation at 25 °C and 60 % RH [+ K] |
0.1 |
0.1 |
Temperature fluctuation at 40 °C and 75 % RH [+ K] |
0.1 |
0.1 |
Temperature range [°C] |
10 to 70 |
10 to 70 |
Temperature variation at 25 °C and 60 % RH [+ K] |
0.3 |
0.3 |
Temperature variation at 40 °C and 75 % RH [+ K] |
0.3 |
0.3 |
Electrical data |
|
|
Nominal power [kW] |
1.4 |
1.4 |
Phase (Nominal voltage) |
1~ |
1~ |
Power frequency [Hz] |
50/60 |
50/60 |
Rated Voltage [V] |
200 to 230 |
200 to 230 |
Unit fuse [A] |
16 |
16 |
Doors |
|
|
Unit doors |
1 |
1 |
Internal Dimensions |
|
|
Depth [mm] |
485 |
485 |
Height [mm] |
785 |
785 |
Width [mm] |
650 |
650 |
Measures |
|
|
Interior volume [L] |
247 |
247 |
Load per rack [kg] |
30 |
30 |
Net weight of the unit (empty) [kg] |
161 |
161 |
permitted load [kg] |
100 |
100 |
Wall clearance back [mm] |
100 |
100 |
Outer dimensions |
|
|
Depth net [mm] |
800 |
800 |
Height net [mm] |
1460 |
1460 |
Width net [mm] |
925 |
925 |
Environment-specific data |
|
|
Energy consumption at 40 °C and 75 % RH [Wh/h] |
400 |
400 |
Sound-pressure level [dB(A)] |
52 |
52 |
Fixtures |
|
|
Number of shelves (std./max.) |
2/9 |
2/9 |
1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C
+3 °C and a power supply voltage fluctuation of
+10 %.
The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber.
Technical data refers to 100 % fan speed.
All indications are average values, typical for units produced in series.
We reserve the right to change technical specifications at any time.
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde
There are no reviews yet.