BINDER CO2 incubator CB 170
The BINDER CO2 incubator CB 170 is a versatile incubator that has been specially developed for use in scientific laboratories and medical research facilities. It is ideal for the cultivation of microorganisms, insect and animal cultures as well as for various breeding and development processes. The CB 170 is particularly useful for the study and analysis of cell behavior and growth. Thanks to its precise control and homogeneous humidity and temperature conditions, it offers optimal conditions for a wide range of applications. Similar to the BINDER CO2 incubator CB 160, O2 control, the CB 170 provides a reliable and controlled environment for sensitive cultures.
Technical data and functions
The BINDER CO2 incubator CB 170 is characterized by a variety of technical features that make it an indispensable device in any laboratory:
-
Incubator type: CO2 incubator
-
Maximum load: 11 - 50 kg
-
Internal volume: 170 liters
-
Temperature range: +4 °C to +60 °C
-
Dimensions (external): 680 mm (width) x 870 mm (height) x 715 mm (depth)
- Dimensions(inside): 560 mm (width) x 600 mm (height) x 505 mm (depth)
-
Recovery time after door opening: 6 minutes at 37 °C
-
CO2 range: 0 to 20 % by volume
-
Humidity range: 90 to 95 % relative humidity
-
Energy consumption: 55 Wh/h at 37 °C
-
Sound pressure level: 41 dB(A)
The CB 170 has a variety of functions that enable precise control and monitoring of the incubation conditions:
-
Controller: Clear display of all relevant parameters
-
Menu navigation: Uncomplicated and intuitive operation
-
Electronic chart recorder: For the graphical display of process parameters
-
VENTAIRTM air jacket system: Available depending on model
-
APT.line preheating chamber technology: Ensures even temperature distribution
-
Natural convection: For gentle air circulation
-
Programmable exhaust air flap: Enables individual adjustment of the fresh air supply
-
Temperature selector limiter: With visual alarm for additional safety
-
Door lock: Prevents unintentional opening during operation
Certifications and standards
The BINDER CO2 incubator CB 170 meets the requirements of DIN 12880:2007 and is manufactured according to BINDER factory standards. This guarantees the highest quality and reliability in daily use.
Application examples
The CB 170 is ideal for a wide range of applications in research and medicine:
-
Cell cultivation: optimal conditions for the growth and examination of cell cultures
-
Microbiological research: Cultivation of microorganisms under controlled conditions
-
Animal and insect cultures: Suitable for the breeding and development of insect and animal cultures
-
Hatching processes: Support in the development and hatching of eggs and larvae
-
Pharmaceutical research: Investigation of cell behavior and cell reactions to various substances
FAQs
How long is the recovery time after a door opening?
The recovery time after a 30-second door opening is about 6 minutes at 37 °C. This ensures a rapid return to optimal incubation conditions.
What CO2 concentrations can be set in the CB 170?
The CB 170 allows CO2 concentrations to be set in the range from 0 to 20 % by volume. This offers flexibility for different applications and experiments.
Is the CB 170 suitable for cultivating cell cultures?
Yes, the CB 170 is ideally suited for the cultivation of cell cultures. The precise control of temperature and CO2 concentration as well as the homogeneous humidity conditions create ideal growth conditions.
What safety functions does the CB 170 offer?
The CB 170 is equipped with a temperature selector limiter with visual alarm to protect against overheating. It also has a door lock that prevents unintentional opening during operation.
Conclusion
The BINDER CB 170 CO2 incubator is a versatile and reliable device that is indispensable in many areas of research and medicine. With its precise control and monitoring functions, it offers optimum conditions for a wide range of applications. Similar to the BINDER CO2 Incubator C170-230V/120V, the CB 170 is an excellent choice for laboratories that demand the highest standards of quality and reliability.
Load max.: |
11 - 50 kg |
Width outside (incubators,...): |
680 mm |
Width inside (incubators,...): |
560 mm |
Maximum temperature (heat): |
+ 60 °C |
Height outside (incubators,...): |
870 mm |
Height inside (incubators,...): |
600 mm |
Incubator model: |
CO2 incubator |
Interior volume: |
101 - 200 l |
Depth outside (incubators,...): |
715 mm |
Depth inside (incubators,...): |
505 mm |
Lowest temperature (cooling): |
+ 4 °C |
Item weight: |
95,00 kg
|
BINDER CO2 Incubator |
CB 170-230V 1 |
CB 170-230V-O 1 |
CB 170-230V-F 1 |
CB 170-230V-OF 1 |
Option model
|
Standard
|
with O2 control
|
With active humidification
|
With O2 control 0.2-20% and active humidification |
Performance Data Temperature |
|
|
|
|
Recovery time after 30 seconds door open at 37 °C [min] |
6 |
6 |
6 |
6 |
Temperature fluctuation at 37 °C [+ K] |
0.1 |
0.1 |
0.1 |
0.1 |
Temperature range 4 °C above ambient temperature to [°C] |
60 |
- |
- |
- |
Temperature range 6 °C above ambient temperature to [°C] |
- |
60 |
60 |
60 |
Temperature variation at 37 °C [+ K] |
0.3 |
0.4 |
0.4 |
0.4 |
Performance Data Climate |
|
|
|
|
Humidity range [% RH] |
90 to 95 |
90 to 95 |
90 to 95 |
50 to 95 |
CO2-Data |
|
|
|
|
CO2 measurement |
IR |
IR |
IR |
IR |
CO2 range [Vol.-% CO2] |
0 to 20 |
0 to 20 |
0 to 20 |
0 to 20 |
CO2 Recovery time after 30 seconds door open at 5 Vol.-% CO2 [min] |
5 |
5 |
5 |
5 |
O2-Data |
|
|
|
|
O2 control ranges with option: O2 range [Vol.-% O2] |
- |
10 to 95 |
- |
10 to 95 |
O2 Recovery time after 30 seconds door open at 5 Vol.-% O2 [min] |
- |
10 |
- |
12 |
Standard O2 control ranges: O2 range [Vol.-% O2] |
- |
0.2 to 20 |
- |
0.2 to 20 |
Electrical data |
|
|
|
|
Nominal power [kW] |
1.4 |
1.4 |
1.4 |
1.4 |
Phase (Nominal voltage) |
1~ |
1~ |
1~ |
1~ |
Power frequency [Hz] |
50/60 |
50/60 |
50/60 |
50/60 |
Rated Voltage [V] |
200 to 240 |
200 to 240 |
200 to 240 |
200 to 240 |
Unit fuse [A] |
10 |
10 |
10 |
10 |
Doors |
|
|
|
|
Inner doors |
1 |
1 |
1 |
1 |
Unit doors |
1 |
1 |
1 |
1 |
Internal Dimensions |
|
|
|
|
Depth [mm] |
505 |
505 |
505 |
505 |
Height [mm] |
600 |
600 |
600 |
600 |
Width [mm] |
560 |
560 |
560 |
560 |
Measures |
|
|
|
|
Interior volume [L] |
170 |
170 |
170 |
170 |
Load per rack [kg] |
10 |
10 |
10 |
10 |
Net weight of the unit (empty) [kg] |
95 |
95 |
95 |
95 |
permitted load [kg] |
30 |
30 |
30 |
30 |
Wall clearance back [mm] |
100 |
100 |
100 |
100 |
Wall clearance sidewise [mm] |
50 |
50 |
50 |
50 |
Outer dimensions |
|
|
|
|
Depth net [mm] |
715 |
715 |
715 |
715 |
Height net [mm] |
870 |
870 |
870 |
870 |
Width net [mm] |
680 |
680 |
680 |
680 |
Environment-specific data |
|
|
|
|
Energy consumption at 37 °C [Wh/h] |
55 |
55 |
55 |
55 |
Sound-pressure level [dB(A)] |
41 |
41 |
41 |
41 |
Fixtures |
|
|
|
|
Number of shelves (std./max.) |
3/6 |
3/6 |
3/6 |
3/6 |
BINDER CO2 Incubator |
CB 170UL-120V1 |
CB 170UL-120V-O1 |
CB 170UL-120V-F1 |
CB 170UL-120V-OF1 |
Option model
|
Standard
|
with O2 control
|
With active humidification
|
With O2 control 0.2-20% and active humidification |
Performance Data Temperature |
|
|
|
|
Recovery time after 30 seconds door open at 37 °C [min] |
6 |
6 |
6 |
6 |
Temperature fluctuation at 37 °C [+ K] |
0.1 |
0.1 |
0.1 |
0.1 |
Temperature range 4 °C above ambient temperature to [°C] |
60 |
- |
- |
-0 |
Temperature range 6 °C above ambient temperature to [°C] |
- |
60 |
60 |
60 |
Temperature variation at 37 °C [+ K] |
0.3 |
0.4 |
0.4 |
0.4 |
Performance Data Climate |
|
|
|
|
Humidity range [% RH] |
90 to 95 |
90 to 95 |
50 to 95 |
50 to 95 |
CO2-Data |
|
|
|
|
CO2 measurement |
IR |
IR |
IR |
IR |
CO2 range [Vol.-% CO2] |
0 to 20 |
0 to 20 |
0 to 20 |
0 to 20 |
CO2 Recovery time after 30 seconds door open at 5 Vol.-% CO2 [min] |
5 |
5 |
5 |
5 |
O2-Data |
|
|
|
|
O2 control ranges with option: O2 range [Vol.-% O2] |
- |
10 to 95 |
- |
10 to 95 |
O2 Recovery time after 30 seconds door open at 5 Vol.-% O2 [min] |
- |
10 |
- |
12 |
Standard O2 control ranges: O2 range [Vol.-% O2] |
- |
0.2 to 20 |
- |
0.2 to 20 |
Electrical data |
|
|
|
|
Nominal power [kW] |
1.4 |
1.4 |
1.4 |
1.4 |
Phase (Nominal voltage) |
1~ |
1~ |
1~ |
1~ |
Power frequency [Hz] |
50/60 |
50/60 |
50/60 |
50/60 |
Rated Voltage [V] |
100 to 120 |
100 to 120 |
100 to 120 |
100 to 120 |
Unit fuse [A] |
16 |
16 |
16 |
16 |
Doors |
|
|
|
|
Inner doors |
1 |
1 |
1 |
1 |
Unit doors |
1 |
1 |
1 |
1 |
Internal Dimensions |
|
|
|
|
Depth [mm] |
505 |
505 |
505 |
505 |
Height [mm] |
600 |
600 |
600 |
600 |
Width [mm] |
560 |
560 |
560 |
560 |
Measures |
|
|
|
|
Interior volume [L] |
170 |
170 |
170 |
170 |
Load per rack [kg] |
10 |
10 |
10 |
10 |
Net weight of the unit (empty) [kg] |
95 |
95 |
95 |
95 |
permitted load [kg] |
30 |
30 |
30 |
30 |
Wall clearance back [mm] |
100 |
100 |
100 |
100 |
Wall clearance sidewise [mm] |
50 |
50 |
50 |
50 |
Outer dimensions |
|
|
|
|
Depth net [mm] |
715 |
715 |
715 |
715 |
Height net [mm] |
870 |
870 |
870 |
870 |
Width net [mm] |
680 |
680 |
680 |
680 |
Environment-specific data |
|
|
|
|
Energy consumption at 37 °C [Wh/h] |
55 |
55 |
55 |
55 |
Sound-pressure level [dB(A)] |
41 |
41 |
41 |
41 |
Fixtures |
|
|
|
|
Number of shelves (std./max.) |
3/6 |
3/6 |
3/6 |
3/6 |
1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C
+3 °C and a power supply voltage fluctuation of
+10%.
The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber.
All indications are average values, typical for units produced in series.
We reserve the right to change technical specifications at any time.
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde
There are no reviews yet.