The KBW 240 from Binder is a growth cabinet and can be used in many areas in laboratories or medicine. You can use the device for many different applications. In the laboratory or in medicine, these include the cultivation of microorganisms, bacteria or animal cultures as well as numerous incubation or development processes. With the KBW 240 you can also observe the behaviour of cells and their growth. It helps you to draw better conclusions with regard to your work or the investigation.
The KBW 240: Reliable support for research, medicine and laboratory work
Binder incubators are mainly used by our customers for both bacterial and eukaryotic cells. For example, temperature, humidity and other conditions such as carbon dioxide and oxygen levels can be individually regulated to create and maintain a specific microclimate in the incubator's atmosphere.
Depending on which model you choose, it has a wide range of features:
- Ergonomic control and information panel
- Handy handle bar
- Optional drawers and shelves
- Stainless steel interior
- Easy to clean
- Low power consumption
- Environmentally friendly thanks to low GWP value
- Low noise level
- Practical locking mechanism
- Membrane keypad with clear symbols
- Digital temperature display and setting via LED display
- Optimum temperature distribution in the entire usable space
- And many other special features!
Please contact our service team.
Cabinet type: Growth cabinetMax. load: 51 - 100 kgInternal volume: 201 - 300 l
Would you like to learn more about our versatile models and especially about the KBW 240?
Get to know even more extras of the KBW 240 model!
Our team of trained advisors guarantees that you will receive the best equipment for your area of expertise. Do you have questions about the different models, their functions or the manufacturers?
We look forward to your enquiry and will be happy to advise you! You can reach us by phone at +49 30 2096579 00 or by e-mail at info@medsolut.com.
Load max.: |
51 - 100 kg |
Width outside (incubators,...): |
925 mm |
Width inside (incubators,...): |
650 mm |
Maximum temperature (heat): |
+ 70 °C |
Height outside (incubators,...): |
1465 mm |
Height inside (incubators,...): |
785 mm |
Interior volume: |
201 - 300 l |
Cabinet type: |
growth chamber |
Depth outside (incubators,...): |
800 mm |
Depth inside (incubators,...): |
485 mm |
Lowest temperature (cooling): |
0 °C |
Item weight: |
195,00 kg
|
BINDER Growth chamber |
KBW 240-230V1) |
Performance Data Temperature |
|
Temperature range without illumination cassettes [°C] |
0...70 |
Temperature range with 100% illumination [°C] |
5...60 |
Temperature variation with 100% illumination [± K] |
0.5 |
Temperature variation without illumination cassettes [± K] |
0.5 |
Temperature fluctuation without illumination cassettes [± K] |
0.1 |
Temperature fluctuation with 100% illumination [± K] |
0.2 |
Lightdata per Illumination Cassettes2) |
|
Daylight tubes [W/m2] |
24 |
Daylight tubes [lx] |
9000 |
Fluora growth lamps [W/m2] |
23 |
Fluora growth lamps [lx] |
7500 |
Arabidopsis lamps [W/m2] |
32 |
Arabidopsis lamps [lx] |
11000 |
Electrical data |
|
Rated Voltage [V] |
200...240 |
Power frequency [Hz] |
50 |
Nominal power [kW] |
1.4 |
Unit fuse [A] |
16 |
Phase (Nominal voltage) [ph] |
1 |
Outer dimensions not incl. fittings and connections |
|
Width net [mm] |
925 |
Height net [mm] |
1465 |
Depth net [mm] |
800 |
Wall clearance back [mm] |
100 |
Wall clearance sidewise [mm] |
100 |
Doors |
|
Inner doors |
1 |
Unit doors |
1 |
Internal Dimensions |
|
Width [mm] |
650 |
Height [mm] |
785 |
Depth [mm] |
485 |
Measures |
|
Interior volume [L] |
247 |
Net weight of the unit (empty) [kg] |
195 |
permitted load [kg] |
100 |
Load per rack [kg] |
30 |
Environment-specific data |
|
Energy consumption at 37 °C and with illumination [Wh/h] |
450 |
Sound-pressure level [dB(A)] |
53 |
Fixtures |
|
Number of shelves (std./max.) |
2/17 |
Number of illumination cassettes (std./max.) |
2/2 |
1) All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
2) Average value, measured at 25 °C with a spherical sensor (±10 %) by 12 cm below the light cassette. The values given in W/m2 refer to global radiation.
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde
There are no reviews yet.