Hettich under-table centrifuge ROTANTA 460 RC (with cooling)

10.735,00


  • Certified advice
  • Insured shipping up to € 25,000
  • Buyer protection
Secure payment

Secure payment

Robust laboratory centrifuge from Andreas Hettich

With the ROTANTA 460 RC from Andreas Hettich you can ensure safe and clean work in the laboratory. You can use the instrument especially for activities in medical diagnostics, DNA research, for work in blood banks as well as in clinical laboratories.

Amazing performance and long service life: The ROTANTA 460 RC from Andreas Hettich can perform a large number of runs at the maximum possible speed. The ROTANTA 460 RC is the optimal centrifuge for any type of separation process and can be used in a wide variety of ways. Depending on which model you choose, you can expect a mix of features.

The laboratory devices from Andreas Hettich already come with various functions in the standard equipment. Via the user-friendly display you can, among other things, choose exactly the right one for your needs from various programs. An innovative microprocessor control system ensures smooth operation and continuous control during the working process. The safety system allows you to view and adjust current error messages immediately. In addition, the unit has an energy-efficient ventilation system that keeps it from overheating.

Enormous power and reliability

Centrifuge type: floor standing centrifuge
Dimensions (H x W x D): 683 x 554 x 697 mm
Connected load: 1800 VA
Frequency: 50 Hz
Weight: 140 kg
Cooling: infinitely variable from -20 to + 40 °C

The ROTANTA 460 RC is a free-standing centrifuge and is therefore ideal for laboratories where space is at a premium. Not only can you move it flexibly from one place to another. Thanks to its practical shape, it is generally very space-saving.

A centrifuge usually works using the so-called mass inertia, which is why it is usually used for activities such as substance separation. It is thus used, for example, for the separation of blood and sera, but also emulsions or gas mixtures.

Angle rotors like the ROTANTA 460 RC are usually used by our customers for complete clarifications of pellets of macro-molecules and of suspensions.

Do you need more details about the ROTANTA 460 RC?

Let us advise you individually

Our team of discerning professionals wants you to get the best instruments for your laboratory. Do you have questions about our various centrifuges, centrifuges with vortex function, their advantages or the respective manufacturers?

We will be happy to assist you and can be reached around the clock by phone at +49 30 2096579 00 or by e-mail at [email protected] We look forward to hearing from you!

Additional information

Weight 160 kg
Rotor type

Ausschwingrotor, swing-out rotor, Winkelrotor

Model of centrifuge

floorstanding centrifuge, Standzentrifuge

Capacity of vessels

1,5 ml, 1.5 ml, 2 ml, 250 ml, 750 ml, 94 ml

Speed max.

15000 rpm

Cooling, heating

cooling, Kühlung

Dimensions (H x W x D) (centrifuges)

683 x 554 x 697 mm

Consumption (Centrifuges)

1800 VA

Frequency (Centrifuges)

50 Hz

Weight approx. (centrifuges)

140 kg

Frequently used rotors

Angle rotor for 6 x 250 ml (25°), max. RCF 14.025, Ausschwingrotor für 4 x 750 ml (90°), max. RCF 5.063, Ausschwingrotor für max. 12 Mikrotiterplatten (90°), max. RCF 6.446, Winkelrotor für 30 x 1,5 / 2,0 ml (45°), max. RCF 24.400, Winkelrotor für 6 x 250 ml (25°), max. RCF 14.025

Capacity max.

4 x 750 ml (im Ausschwingrotor), 6 x 250 ml (im Winkelrotor), 6 x 250 ml (in an angle rotor)

Cooling (Centrifuges)

Infinitely variable from -20 °C to +40 °C, stufenlos regelbar von -20 bis + 40 °C

Duration

1 s – 99 h : 59 min : 59 s, Dauerlauf, Kurzlauf, 1 sec – 99 h : 59 min : 59 sec, continuous run, short cycle mode

RCF max.

24400 xg

Voltage (Centrifuges)

200 – 240 V

Emission, Immunity

EN / IEC 61326-1, class B, EN / IEC 61326-1, Klasse B