ENVAIR safety cabinet eco safe Basic Plus double blower
The ENVAIR eco safe Basic Plus double blower safety cabinet is a state-of-the-art safety cabinet specially developed for applications in optics, laser, semiconductor and electronics technology. This workbench provides a clean, particle and germ-free environment that ensures the protection of both products and employees. Thanks to its outstanding features and certifications, it is a preferred choice for professionals who need to maintain the highest safety and quality standards. Similar to the FASTER SafeFAST Elite double blower safety cabinet, the ENVAIR safety cabinet offers a reliable and efficient solution for demanding work environments.
Technical data and features
The ENVAIR eco safe Basic Plus double blower safety cabinet is characterized by the following technical data and features:
-
Safety class: Class II
-
Width: 1001 mm - 1100 mm, 1301 mm - 1400 mm, 1601 mm - 1700 mm, 1901 mm - 2000 mm
-
Depth: 801 mm - 900 mm
-
Height: 1401 mm - 1500 mm
-
General dimensions (WxHxD): 1045x1500x860 mm, 1350x1500x860 mm, 1655x1500x860 mm, 1960x1500x860 mm
-
Usable dimensions (WxHxD): 887x740x580 mm, 1192x740x580 mm, 1497x740x580 mm, 1802x740x580 mm
-
Working opening: 200 mm
-
Max. Front opening: 440 mm
-
Weight: 170 kg, 195 kg, 225 kg, 260 kg
-
Exhaust air: 290 m³/h, 390 m³/h, 485 m³/h, 585 m³/h
-
Noise level: < 53 dB(A), < 54 dB(A), < 55 dB(A), < 56 dB(A)
-
Light intensity: > 1100 lux, > 1200 lux, > 1300 lux
-
Electrical connection: 1Ph+E - 230V 50Hz
-
Heat output: 175 W, 240 W, 295 W, 360 W
-
Total current: 1.9 A, 2.1 A, 3.4 A, 3.6 A
-
Protection class / IP: 1 / 20
-
Internal fuse protection: 4 A
-
Power consumption: 256 W, 364 W, 539 W, 644 W
Certifications and standards
The ENVAIR safety cabinet eco safe Basic Plus double blower complies with the European standards EN 12469:2000 and has a TÜV certificate. These certifications ensure that the workbench meets the highest safety and quality standards and therefore offers a reliable and safe working environment.
Application examples
This safety workbench is often used in the following areas:
-
Optics technology: For the manufacture and processing of optical components, where a particle and germ-free environment is essential.
-
Laser technology: To protect sensitive laser components and prevent contamination during production.
-
Semiconductor technology: For the production and processing of semiconductors where the highest purity requirements apply.
-
Electronics technology: To protect electronic components and prevent contamination during assembly and testing.
FAQs
What safety class does the ENVAIR eco safe Basic Plus double blower safety cabinet have?
The safety cabinet belongs to safety class II, which means that it guarantees both product protection and personal protection.
How loud is the safety cabinet during operation?
Depending on the model, the noise level of the safety cabinet is between < 53 dB(A) and < 56 dB(A), making it a quiet and pleasant working environment.
What certifications does the safety cabinet have?
The ENVAIR eco safe Basic Plus double blower safety cabinet complies with the European standard EN 12469:2000 and has a TÜV certificate.
How large is the working opening of the safety cabinet?
The working opening of the safety cabinet is 200 mm, which provides sufficient space for most applications.
Conclusion
The ENVAIR eco safe Basic Plus double blower safety cabinet is an excellent choice for professionals in optics, laser, semiconductor and electronics technology. With its outstanding technical data, certifications and versatile application options, it offers a safe and efficient solution for demanding work environments. Similar to the FASTER SafeFAST Classic double blower safety cabinet, it offers a reliable and high-quality working environment for the highest demands.
Width: |
1001 mm - 1100 mm, 1301 mm - 1400 mm, 1601 mm - 1700 mm, 1901 mm - 2000 mm |
Device type: |
safety cabinet |
Height: |
1401 mm - 1500 mm |
Safety class: |
class II |
Depth: |
801 mm - 900 mm |
Safety cabinets |
ENVAIR eco safe Basic Plus Class II |
|
0.9 m |
1.2 m |
1.5 m |
1.8 m |
Overall Dimensions WxHxD (1) (mm) |
1045x1500x860 |
1350x1500x860 |
1655x1500x860 |
1960x1500x860 |
Useful Dimensions WxHxD (mm) |
887x740x580 |
1192x740x580 |
1497x740x580 |
1802x740x580 |
Working aperture |
200 mm |
200 mm |
200 mm |
200 mm |
Max front aperture |
440 mm |
440 mm |
440 mm |
440 mm |
Weight |
170 kg |
196 kg |
225 kg |
260 kg |
Exhaust flow rate |
290 m3/h |
390 m3/h |
485 m3/h |
585 m3/h |
Noise level (2) |
< 53 dB(A) |
< 54 dB(A) |
< 55 dB(A) |
< 56 dB(A) |
Lighting level |
>1100 lux |
>1200 lux |
>1300 lux |
>1300 lux |
Electrical Data |
1Ph+E - 230V 50Hz |
1Ph+E - 230V 50Hz |
1Ph+E - 230V 50Hz |
1Ph+E - 230V 50Hz |
Power consumption |
175 W |
240 W |
295 W |
360 W |
Current consumption (2) (3) |
1.9 A |
2.1 A |
3.4 A |
3.6 A |
Electrical class / IP |
1 / 20 |
1 / 20 |
1 / 20 |
1 / 20 |
Internal electrical outlet |
4 A |
4 A |
4 A |
4 A |
Heat emission |
175 W |
240 W |
295 W |
360 W |
(1) The total depth of the cabinet can be easily reduced to 780 mm by removing the back panel
(2) At operation condition according to EN12469: 2000
(3) Clean filters, lighting activated, internal outlet load excluded
Envair offers service in pure culture. We do not simply sell our units to you but will assist you gladly from A to Z.
Delivery:
We deliver all units ex works.
Set-up service and packaging disposal are included upon request.
Service:
- 24h at site service and 24h free of charge phone hotline
- 7 days a week
Spare parts guaranty:
- 10 years
- Availability within 24h
- Ex stock Emmendingen
Qualification:
- IQ/OQ
- GMP
- GAMP
- 21 CFR Part 11
Decontamination:
We carry out microbiological decontaminations with most modern H2O2 generators in Cleanrooms, Isolators and Safety Cabinets.
Maintenance:
- Microbiological Safety Cabinets DIN 12469
- Cytotoxic Dispensing Cabinets with KI-discus test DIN 12980
- Laminar Flow Cabinets
- Laboratory Fume Hoods
- Cytotoxic Dispensing Isolator DIN 12980
- Isolator EN 14644-7
- Cleanrooms
- Autoclaves
- CO2 Incubator
- Ultra Low Temperature Freezer -86 °C
Service by professional staff. All works are carried out by service technicians qualified by TÜV Nord.
Maintenance contract:
Regular terms of maintenance increase your safety.
With a maintenance contract we guarantee the complete check of all functions of your units. We will contact you reliably in regular terms.
Guaranty and Warranty:
Combined with an ENVAIR maintenance contract we offer a 2-year warranty to all units. Excepted are consumables and wearing parts as well as compressed air components.
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde
There are no reviews yet.