PHOENIX Instrument rotor with lid 24 x 1.5/2 ml
The PHOENIX Instrument Rotor with Lid 24 x 1.5/2 ml is an indispensable accessory for laboratories working with centrifuges. This rotor is particularly suitable for applications in blood group serology and other biomedical tests. Its high capacity and reliability make it a preferred choice for many laboratory professionals. Similar to the Hettich hematocrit rotor 24x, this rotor offers high efficiency and precision.
Technical details and advantages
The PHOENIX Instrument Rotor is specially designed to hold 24 tubes with a volume of 1.5 to 2 ml. This enables a high sample capacity and therefore efficient processing of large sample volumes. The rotor is made of robust material that ensures a long service life and high resistance to chemical influences.
-
Capacity: 24 x 1.5/2 ml
-
Material: High-quality, chemical-resistant material
-
Application: Blood group serology, biomedical tests
-
Compatibility: Suitable for various centrifuge models
Another advantage of this rotor is its ability to operate at maximum permissible speeds without sacrificing stability or performance. This is particularly important for applications that require high centrifugal force, such as the separation of blood components.
Certifications and standards
The PHOENIX Instrument Rotor complies with all relevant standards and certifications required for laboratory equipment. These include, among others:
-
CE marking: Conformity with European safety, health and environmental protection requirements
-
ISO certification: Meets international standards for quality and safety
Application examples
This rotor is ideal for a variety of applications in medical and life science research. Some specific application examples include:
-
Blood group serology: For the determination of blood groups and Rh factors
-
Plasmapheresis: separation of plasma and blood cells
-
DNA extraction: Isolation of DNA from blood samples
-
Protein purification: Separation and purification of proteins from biological samples
For similar applications, the microhaematocrit rotor 24x50 mm for Sigma 1-14, 1-14K could also be considered.
FAQs
How do I clean the PHOENIX Instrument Rotor?
-
Answer: The rotor should be cleaned after each use with a mild detergent and distilled water. Avoid aggressive chemicals that could damage the material.
Can the rotor be autoclaved?
-
Answer: Yes, the rotor is autoclavable and can be sterilized at 121°C for 20 minutes.
Which centrifuge models are compatible?
-
Answer: The rotor is compatible with most standard centrifuges. For specific models, please consult the manual or the manufacturer.
What is the maximum speed for this rotor?
-
Answer: The maximum speed is 15,000 rpm. It is important not to exceed this limit to ensure the integrity of the rotor.
Conclusion
The PHOENIX Instrument Rotor with Lid 24 x 1.5/2 ml is an excellent choice for laboratories that need a reliable and efficient solution for their centrifuge applications. With its high capacity, robust design and compatibility with various centrifuge models, this rotor offers excellent performance and longevity. For alternative options, the Hettich angled rotor 24-fold 40° for MIKRO 200 / 200 R could also be considered.