Carbolite TF1 Small 1200 °C horizontal tube furnace
The Carbolite TF1 Small 1200 °C horizontal tube furnace is a versatile and reliable high-temperature furnace designed specifically for laboratory and industrial applications. With a maximum operating temperature of 1200 °C, this furnace is ideal for a wide range of heat treatment processes such as drying, hardening, ashing, sintering and brazing under vacuum. Thanks to its robust design and the ability to operate in inert gas or vacuum atmospheres, the TF1 Small is an excellent choice for demanding research and production environments.
Similar to the Carbolite TF3 Medium 1200 °C horizontal 3-zone tube furnace, the TF1 Small offers high temperature stability and precision, making it an indispensable tool for material testing and sintering processes.
Technical data and features
The Carbolite TF1 Small 1200 °C horizontal tube furnace is characterized by the following technical specifications:
-
Maximum temperature: 1200 °C
-
Power: 0.75 kW, 1.5 kW, 2 kW, 2.5 kW
-
Heated length: 150 mm, 300 mm, 450 mm, 600 mm
-
Tube length: 430 mm, 580 mm, 600 mm, 730 mm, 750 mm, 880 mm, 900 mm, 1050 mm
-
Constant zone: 93 mm, 177 mm, 318 mm, 474 mm
-
Dimensions (H x W x D): 575 mm x 485 mm x 480 mm to 575 mm x 795 mm x 480 mm
-
Thermocouple type: N
-
Weight: 31 kg to 56 kg
These features make the TF1 Small a flexible and powerful device that can be adapted to different requirements. The ability to select different pipe lengths and heated zones enables precise control of temperature distribution and stability.
Certifications and standards
The Carbolite TF1 Small 1200 °C horizontal tube furnace meets the highest safety standards and is equipped with the necessary certifications. This not only ensures user safety, but also compliance with international standards and regulations.
Application examples
The TF1 Small is ideal for a wide range of applications in research and industry:
-
Sintering: perfect for the production of ceramics and metal powders.
-
Material testing: Ideal for testing material properties under high temperatures.
-
Drying and hardening: Efficient for the treatment of materials in dental laboratories and toolmaking.
-
Ashing: Suitable for analyzing organic materials.
-
Brazing under vacuum: Ideal for the production of high-precision components.
FAQs
What power supply is required for the TF1 Small?
- The TF1 Small requires a power supply of 220-240 volts and can be operated with one phase. The maximum current requirement is 16 amps per phase.
Can the oven be operated in an inert gas atmosphere?
- Yes, the TF1 Small can be operated in an inert gas atmosphere, making it ideal for sensitive materials that require a controlled environment.
How long does it take for the oven to reach the maximum temperature?
- The heat-up time to the maximum temperature of 1200 °C is between 35 and 45 minutes, depending on the model.
What safety precautions should be observed?
- It is important not to exceed the maximum heating rate of +5 °C/min when using a ceramic working tube. In addition, the maximum continuous operating temperature should be 100 °C below the maximum temperature.
Conclusion
The Carbolite TF1 Small 1200 °C horizontal tube furnace is a versatile and reliable high-temperature furnace that is ideal for a wide range of applications in research and industry. With its robust design, high temperature stability and the ability to work in different atmospheres, it offers excellent performance and flexibility. Similar products such as the Carbolite FST 1300 °C horizontal hinged tube furnace offer additional options for specific requirements.
Heated length: |
150 mm, 300 mm, 450 mm, 600 mm |
Width outside (oven): |
485 mm, 495 mm, 645 mm, 795 mm |
Height outside (oven): |
575 mm |
Constant zone: |
93 mm, 177 mm, 318 mm, 474 mm |
Power (oven): |
0.75 kW, 1,5 kW, 2 kW, 2,5 kW |
Stove appliance type: |
tube furnace |
Oven temperature max.: |
1200°C |
Suitable for application: |
Sintering, Material tests |
Pipe diameter (outside): |
60 mm |
Pipe length: |
430 mm, 580 mm, 600 mm, 730 mm, 750 mm, 880 mm, 900 mm, 1050 mm |
Depth outside (oven): |
480 mm |
Carbolite
Universal-
Tube oven
TF1 Small |
Maximum
Temperature
(°C)
|
Heating time
(minutes) |
Maximum
outer diameter
Working tube
(mm) |
Heated
length
(mm) |
Recommended
tube length under
air atmosphere
(mm) |
Recommended
tube length under
inert gas atmosphere
(mm) |
Dimensions
outside horizontal
H x W x D
(mm) |
Dimensions
Control unit
H x W x D
(mm) |
Length homogeneous
zone ±5 °C
(mm) |
Maximum
power
(W) |
Thermocouple
Type |
Weight
(kg) |
TF1 12/60/150 |
1200 |
40 |
60 |
150 |
430 |
600 |
575 x 485 x 480 |
230 x 485 x 480 |
93 |
750 |
N |
31 |
TF1 12/60/300 |
1200 |
35 |
60 |
300 |
580 |
750 |
575 x 495 x 480 |
230 x 485 x 480 |
177 |
1500 |
N |
37 |
TF1 12/60/450 |
1200 |
45 |
60 |
450 |
730 |
900 |
575 x 645 x 480 |
230 x 635 x 480 |
318 |
2000 |
N |
49 |
TF1 12/60/600 |
1200 |
45 |
60 |
600 |
880 |
1050 |
575 x 795 x 480 |
230 x 785 x 480 |
474 |
2500 |
N |
56 |
Please note:
Heating time to continuous operating temperature with empty quartz working tube and fibre insulation plug.
Heating rate when using a ceramic working tube must not exceed +5 °C/min
Holding power measured at continuous operating temperature
Homogeneous zone measured with fibre insulation plugs in both tube ends at 100 °C below maximum temperature
Maximum continuous operating temperature is 100 °C below the maximum temperature
Power supply |
Volt |
Phase |
Amps per phase |
TF1 12/60/_ |
220-240 |
1 phase |
16 |
Please specify desired power supply and mains connection when ordering!
Other power connection configurations on request.
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde
There are no reviews yet.