Spetec protective box PBS series
The Spetec protection box PBS series is a state-of-the-art solution for working under dust-free and sterile conditions. This protective box is mainly used in optics, laser, semiconductor and electronics technology, where a clean, particle- and germ-free environment is essential. Spetec's PBS series meets all European standards and is TÜV approved, making it a reliable choice for demanding applications. Compared to other products such as the Spetec Laminar Flow Box EFBS series, the PBS series offers a particularly large cleanroom work surface and a modular design that avoids space problems.
Technical data and special features
The Spetec PBS series protective box is characterized by the following technical data and special features:
-
Device type: Cleanroom workbench, filter module, product protection
-
Width: 1001 mm - 1100 mm, 701 mm - 800 mm, 1301 mm - 1400 mm, 1601 mm - 1700 mm, 1901 mm - 2000 mm
-
Depth: 701 mm - 800 mm
-
Height: 901 mm - 1000 mm
-
Cleanroom equipment: Laminar flow box
-
Certifications: TÜV-tested, meets all European standards
Special features
-
Maximum safety standard: The protective box offers maximum protection for products and users.
-
High-performance manufacturing: Robust and durable construction.
-
Air quality testing: Ensures optimum air quality.
-
Compliance with occupational exposure limits: Ensures compliance with legal requirements.
-
Modular design: Flexible and space-saving.
-
Wide range of equipment variants: Adaptable to different requirements.
-
Large cleanroom work surface: Provides sufficient space for complex work.
-
Integrated filters: Easy maintenance and filter replacement.
-
Safety glass panes: Increased safety and durability.
-
Various programming modes: Adaptable to specific work requirements.
Application examples
The Spetec protection box PBS series is ideal for the following applications:
-
Optics and laser technology: Protecting sensitive optical components from dust and contamination.
-
Semiconductor production: Ensuring a particle and germ-free environment for the production of semiconductors.
-
Electronics production: Protecting electronic components and circuits from contamination.
-
Medical research and laboratories: Sterile conditions for handling samples and reagents.
Certifications and standards
The Spetec protection box PBS series is TÜV-certified and complies with all relevant European standards. This guarantees maximum safety and reliability in operation. It also meets the requirements of DIN EN ISO 14644 and GMP guidelines, making it an excellent choice for cleanroom applications.
FAQs
How often do the filters of the Spetec protection box PBS series need to be changed?
The filters should be checked regularly and changed at least once a year, depending on the frequency of use and the environment. The integrated filter system ensures easy filter replacement.
Can the protection box be adapted to specific requirements?
Yes, the Spetec PBS series protective box offers a wide range of equipment variants and programming modes that can be adapted to specific work requirements.
What certifications does the Spetec PBS series protective box have?
The protective box is TÜV-certified and meets all European standards as well as the requirements of DIN EN ISO 14644 and GMP guidelines.
Is the protection box suitable for use in semiconductor production?
Yes, the Spetec protection box PBS series is ideal for semiconductor production as it ensures a particle and germ-free environment.
Conclusion
The Spetec protection box PBS series is a first-class solution for applications that require a sterile and particle-free environment. With its wide range of features, modular design and high safety standards, it is an excellent choice for optics, laser, semiconductor and electronics technology. Similar products such as the Spetec Laminar Flow Box FBS series also offer high-quality solutions for cleanroom applications.
Width: |
701 mm - 800 mm, 1001 mm - 1100 mm, 1301 mm - 1400 mm, 1601 mm - 1700 mm, 1901 mm - 2000 mm |
Device type: |
Product protection, clean bench, filter module |
Height: |
901 mm - 1000 mm |
Cleanroom equipment: |
Laminar flow box |
Depth: |
701 mm - 800 mm |
Portable tabletop exhaust hood |
Spetec EBS series |
Type/Size |
EBS 37 |
EBS 56 |
EBS 75 |
EBS 93 |
EBS 112 |
Interior height (mm) |
805 |
805 |
805 |
805 |
805 |
Height with the open door (mm) |
1441 |
1441 |
1441 |
1441 |
1441 |
Outer dimensions W x D x H (mm) |
735 x 793.3 x 940
|
735 x 793.3 x 940
|
735 x 793.3 x 940
|
735 x 793.3 x 940
|
735 x 793.3 x 940
|
Spetec Clean room technology Service
We - as a manufacturer and service provider for clean room technology - provide a range of device variants on the one hand, and fast and universal service assistance on the other hand. Now we have used our many years of experience as a manufacturer to develop a services offering, which allows us to test, service, and maintain your clean room system using state of the art measuring equipment.
Very clean air is not just vital in clinic operating rooms. Highly sensitive production environments, such as those in the semiconductor production, precision engineering, optics and optoelectronics, laser technology, or food processing industries, also demand a sufficient level of ambient air quality. In order to ensure this, flow velocity or filter tests are required at regular intervals.
We offer the following services:
- Particle counts
- Replacing filters in various brands of laminar flow boxes (LF units)
- Finding and fixing leaks
- Determining volume flow rates or flow velocities
- Temperature and relative humidity measurements
-HEPA filter / filter system installation monitoring
- DEHS leak test
- Clean room validation and certification in accordance with EN ISO 14644 and GMP guidelines
We also perform certification within the framework of EN ISO 14644, that is, we record the measurement parameters defined in DIN EN ISO 14644 such as particle counts, flow velocities, etc. All of these parameters are confirmed with a corresponding certificate.
All of the particle measurement devices, air speed, temperature, and humidity sensors we use are tested and calibrated every 12 months.
Our offering includes service and maintenance work as well as certification of clean rooms and laminar flow boxes according to the current national and international guidelines and standards. These include the VDI 2083 and DIN EN ISO 14644 guidelines as well as the US Fed Std. 209E. You receive comprehensive documentation about the measurements and a risk assessment.
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde
There are no reviews yet.