SIGMA 4-16S large volume laboratory centrifuge

5.845,00


  • Certified advice
  • Insured shipping up to € 25,000
  • Buyer protection
Secure payment

Secure payment

Special rotor, angle rotor, swing-out rotor, MTP rotor 4-16S from Sigma laboratory centrifuges for ideal work

The 4-16S from Sigma laboratory centrifuges has established itself over the last few years as an important laboratory component that our customers no longer want to do without. For example, you can use the instrument for work in clinical laboratories, in DNA research and for work with blood banks.

Thanks to its long service life, you can also use the 4-16S for a large number of runs at the highest permissible speeds. The centrifuge can be used for a wide range of applications, including all types of separations. Depending on the model, Sigma laboratory centrifuges have a wide range of expansion and optional features.

The basic equipment includes:

  • Disyplay display
  • A wide range of operating options
  • A smart microprocessor control
  • Error display
  • Sustained ventilation
  • Safety system included
  • Manufacturer’s warranty
  • A practical lid lock
  • Optimal monitoring
    -Timer function
  • Audible alarm signal

Sigma laboratory centrifuges Laboratory centrifuges: discover the features of the 4-16S

Centrifuge type: Universal centrifuge
Dimensions (H x W x D): 489 x 496 x 650 mm
Display: TFT
Temperature range: up to + 70 °C
Frequency: 50/60 Hz
Programs: 60
Control: Lockable control

When you choose universal centrifuges like the 4-16S, you are choosing a true multi-talent. Due to the wide range of functions, the device is used in many different areas. Applications include both routine medical and veterinary testing, using various systems to obtain PRP, and conducting various research in clinical, medical, or cosmetology settings.

A centrifuge usually operates using what is known as inertia and is therefore often used to separate substances. It is thus used, for example, for the separation of gas mixtures, emulsions or suspensions.

Swing-out rotors are usually used for tasks such as analytical or semi-preparative separations.

You can always ask our team of experts for more useful information about the features and characteristics of the item.

Our experts are ready to answer your questions!

Our team of experienced experts guarantees that you will receive the ideal instruments for your needs. Do you have any questions about our versatile instruments, their benefits or the respective manufacturers?

We will be happy to advise you and can always be reached by phone at +49 30 2096579 00 or by e-mail at [email protected] We look forward to hearing from you!

Additional information

Weight 135 kg
Rotor type

Ausschwingrotor, MTP rotor, MTP-Rotor, Spezialrotor, Winkelrotor

Deceleration curves, linear

10

Speed min.

100 rpm

Model of centrifuge

universal centrifuge, Universalzentrifuge

Speed max.

13500 rpm

Dimensions (H x W x D) (centrifuges)

489 x 496 x 650 mm

Acoustic signal, switchable

ja, yes

Display shows dimensions

ja, yes

Display speed / g-force

Drehzahl und Schwerefeld, speed and g-force

Acceleration max.

Rotor 12130: 29 s, Rotor 12256: 78 s

Linear acceleration curves

10

Acceleration curves, quadratic

10

Frequency (Centrifuges)

50/60 Hz

Capacity of vessels

0,2 ml, 0,4 ml, 0,5 ml, 0,75 ml, 0.75 ml, 1,5 ml, 10 ml, 100 ml, 12 ml, 125 ml, 15 ml, 150 ml, 175 ml, 2 ml, 200 ml, 25 ml, 250 ml, 30 ml, 4 ml, 40 ml, 400 ml, 5 ml, 50 ml, 500 ml, 650 ml, 7 ml, 80 ml, 85 ml

Deceleration curves, quadratic

10

Deceleration max.

Rotor 12130: 28 s, Rotor 12256: 108 s

Continous run

ja, yes

Lid release / lid open

Auto lid open, switchable, Autom. Deckelentriegelung bei Laufende, abschaltbar, Autom. Deckelöffnung, abschaltbar

Display (Centrifuges)

TFT

Speed increments (Centrifuges)

10; 1 rpm

Calculation for liquid density

>1,2 g/cm3, >1.2 g/cm3

User defined acceleration curves

10

User defined deceleration curves

10

Brakeless

ja, yes

User defined program name

ja, yes

Deceleration and brakeless

Combination from 1000 – 150 rpm selectable, kombiniert ab 1000 – 150 rpm wählbar

Noise level at max. speed

Rotor 11150: 73 dB (A), Rotor 12130: 73 dB (A)

Rotors, pre programmed

All rotors pre programmed speed, g-force, radius , Alle Rotoren vorprogrammiert; Drehzahl, Schwerefeld, Radius

G-force increments

10;1 xg

Capacity max.

4 x 500 ml

Kinetic energy max.

50486 Nm

Short run

ja, yes

Run monitoring

ja, yes

Power consumption (centrifuges)

1680 W

Max. radius decreaseable  

ja, yes

Microprocessor controlled

ja, yes

Optical display stillstand

ja, yes

Permanent display preselected, current values

ja, yes

Programs (Centrifuges)

60

Weight without rotor

82 kg

Height with open lid

940 mm

Safety (Centrifuges)

4 stelliger freier Zahlencode als Schlüssel, Pop up window end of rotor life time, Startverweigerung bei zu großer Isttemperaturabweichung, Toleranz einstellbar, warnt bei Lebensdauerende des Rotors

Signal length preselectable

ja, yes

Voltage (Centrifuges)

220 – 240 V

Start delay

ja, yes

Controller (Centrifuges)

Control unit lockable, Steuerung verriegelbar

Temperatur setting range

bis + 70 °C, to + 70 °C

Temperature increments

1 °C

Switchable °C, °F

ja, yes

Time setting range

10 sec – 99h 59min

Time increments

60; 1 s

Timing after

erreichter Solldrehzahl, abschaltbar, set speed has been reached, switchable

Counting cycles

Counting cycles centrifuge, each rotor, Zyklenzählung Zentrifuge, jeder Rotor