Retsch vibratory mill MM 500 control sets for temperature monitoring and control
The Retsch MM 500 control sets for temperature monitoring and control have been specially developed for dry, wet and cryogenic grinding. Thanks to their high energy input and integrated temperature control from -100 °C to +100 °C, they are ideal for laboratories that want to grind temperature-sensitive samples quickly and reproducibly. Similar features to the Retsch CryoMill vibrating mill show that efficient cryogenic and high-throughput grinding is becoming increasingly important, which is why many users rely on flexible systems with a sophisticated temperature control option. However, for those who value a larger sample volume, the Retsch Planetary Ball Mill PM 100 is an alternative with a different grinding mechanism configuration.
Versatile areas of application and functional principle
The sets are suitable for homogenization, mechanochemistry, cryogenic grinding and mechanical alloying. The grinding balls hit the sample material with high energy using a horizontal, circular arc-shaped oscillation mechanism. This not only crushes the material, but also mixes it intensively at the same time. The integrated temperature management ensures that temperature-sensitive components or substances can be cooled or heated as required. This makes it possible, for example, to preserve volatile ingredients or run temperature-controlled reactions.
The design of the sets takes a wide range of requirements into account: - Dry or wet grinding as well as cryogenic grinding with frequencies of up to 30 Hz
- Convenient operation via digital or touch display
- Fast, safe clamping of two Screw-Lock grinding bowls (up to 125 ml)
- Hermetically sealed cooling line system for safe handling of liquid nitrogen and thermal fluids
- Quiet operation and ergonomic design
Efficient temperature control in detail
The sets operate in the range from -100 to +100 °C using a patented, indirect cooling concept. This means that open LN2 baths or dry ice are no longer used, which offers significant safety and convenience benefits. The grinding bowls are placed on cooling or heating plates whose temperature is controlled by the respective temperature control fluid (e.g. water, water-glycol mixtures, thermal fluids or liquid nitrogen). When using liquid nitrogen, the optional CryoPad can be placed under the vibrating mill like a docking station to enable precise control between -100 °C and 0 °C.
Technical highlights (excerpt)
- Frequency range: 3-30 Hz (maximum 1800 min-¹)
- Final fineness: up to ~0.1 μm (depending on material)
- Max. Grinding chamber volume: 2 × 125 ml
- Supported grinding modes: dry, wet and cryogenic
- Patented Screw-Lock system for secure fixation of the grinding bowls
- Optional CryoPad for liquid nitrogen (1.2-1.4 bar)
- Compatible with water, water-glycol mixtures and many thermal fluids
- CE-certified
The high flexibility is reflected in different sets:
- LN2 comfort and LN2 economy: each include CryoPad, LN2 autofill (50 l or 150 l), safety valve and connection hose.
- liquid thermal fluid: equipped with a hose set for customer-supplied thermal fluids, chillers or cryostats.
Concrete application examples
- Samples with volatile substances: Cooling prevents the volatilization of temperature-sensitive components in pharmaceutical or food technology samples.
- Mechanochemical reactions: Heating can increase and control the reaction rate.
- Paste production in the food industry: Moderate heating helps to achieve homogeneous mixtures.
- Tissue or plant material: Cryogenic grinding facilitates the comminution of fibrous structures and the preservation of active ingredients.
In addition, low temperatures cause many samples to become brittle, which makes grinding much easier. Temperature monitoring and control also provide safety and reproducibility for mechanochemical processes where temperature can control the course and speed of a reaction.
FAQs
How exactly does temperature control work?
The temperature is set via digital specifications and continuously monitored via integrated sensors in combination with a PID controller. This ensures that the set temperature remains stable throughout the entire grinding process.
Is it possible to operate without liquid nitrogen?
Yes, the sets are compatible with conventional chiller systems or other temperature control liquids. The CryoPad is only required if you want to work directly with liquid nitrogen.
What minimum particle size can be achieved?
Fine particle sizes of 0.1 µm can be achieved for many samples. However, this depends heavily on the hardness and composition of the material as well as the selected grinding settings.
Can I process two different samples in parallel?
Yes, the grinding chamber is designed for two grinding bowls. Each container can be filled with a different sample, for example, as long as the total volumes or the maximum permitted weight are not exceeded.
Is the grinder suitable for continuous operation?
A maximum grinding time of 99 hours can be set so that long processes are also possible. Thanks to special design features, overheating or an increase in pressure is reliably prevented.
Conclusion
These sets offer an excellent combination of powerful shredding, thermal control and a wide range of application scenarios. Particularly temperature-sensitive materials can be processed gently, while the optional CryoPad is suitable for the use of liquid nitrogen. At the same time, operation remains convenient and safe. Anyone who needs temperature-controlled shredding processes will find a professional solution here that can be flexibly adapted to the highest requirements.