This freezer has been specially developed for laboratories and medical facilities and meets high requirements in terms of reliability and temperature stability. Its temperature range of -18 °C to -25 °C makes it ideal for storing sensitive samples, diagnostics or reagents. Its sophisticated design, robust construction and silent cooling ensure a constantly low temperature, while various alarm functions provide early warning of critical situations. The [National Lab Laboratory Refrigerator ProTech] provides similarly robust solutions for sample storage, which can be compared with this model in terms of safety and durability.
Equipment and performance features
This appliance impresses with its well thought-out design and reliable components. Particularly noteworthy are:
- Temperature range from -18 °C to -25 °C - ideal for temperature-sensitive sample material
- Manual defrosting for easy control of appliance hygiene and prevention of ice formation
- Visual and acoustic temperature alarm functions, including over- and under-temperature alarm and door alarm
- Silent cooling system with R600a refrigerant, which is free from CFCs and HCFCs
- Electronic controller with digital display: precise control and convenient monitoring
In addition, the appliance has a potential-free alarm contact. This means it can be connected to an external remote alarm system and integrated into existing security structures. The integrated front feet are height-adjustable, and two castors at the rear also make transportation easier. Additional security is provided by a door lock in combination with an interchangeable door hinge, allowing it to be flexibly adapted to spatial conditions.
The model achieves ultra-precise room partitioning thanks to individually adapted shelves or drawer systems, depending on the version. The ML0422WN version has one mesh shelf, for example, while the ML1626WN already has three integrated mesh shelves. The larger ML3126WN version combines contact evaporator plates with several drawers and flaps, allowing samples to be sorted very clearly. All versions offer an interior made of white plastic, which is easy to clean and ensures a hygienic storage environment.
The outer housing is made of galvanized and white-coated sheet steel, which is extremely resistant to damage and corrosion. Although the door seal is not replaceable, it provides a high level of tightness for reliable protection against the cold. Another plus point is the lack of ignition sources in the interior as standard, meaning that the appliance is also suitable for flammable substances in corresponding containers (with optional usable space feed-through).
Possible certifications and standards
National Lab attaches great importance to compliance with common quality and safety standards. Such refrigerators and freezers are often manufactured in accordance with CE standards and fulfill important laboratory guidelines. This allows GMP regulations to be supported in many areas. Before purchasing or installing, it is advisable to enquire directly about the specific certificates and test certificates in order to cover the respective application professionally.
Application examples
- Storage of enzymes and antibodies in medical research laboratories that require a stable deep-freeze temperature.
- Storage of sensitive medicines or vaccines in pharmacies and clinical settings.
- Long-term storage of DNA samples and cell cultures for biotechnological projects
- Safe storage of microbiological reagents or reference materials.
Even in small research areas, the device can be accommodated in a space-saving manner thanks to its compact dimensions (e.g. the smaller ML0422WN model).
FAQs
How often should manual defrosting be carried out?
This depends on the ice formation. As a rule, it is advisable to defrost the appliance briefly if there is a clear layer of ice in order to maintain cooling capacity and energy efficiency.
Can the door hinge direction be changed yourself?
Yes, the door hinge can be changed. If necessary, it can be changed independently or by technically skilled personnel.
How loud is the cooling system in operating mode?
The device works with silent cooling and generally only generates a low level of background noise. This is a decisive advantage, especially in laboratory operation with sensitive measuring devices.
Does the device offer a remote alarm system?
It has a potential-free contact so that it can be integrated into existing remote monitoring systems. This allows external warning signals to be triggered in the event of temperature deviations.
Conclusion
The freezer models described here meet the demanding requirements of laboratories and medical facilities that require precise and reliably monitored deep-freezing. Thanks to the sophisticated overall concept, robust design and integrated alarm systems, the appliance facilitates compliance with the required safety and quality standards and offers high reliability in daily operation.