The Liebherr L KPv 6527 MediLine laboratory refrigerator is a state-of-the-art refrigerator that has been specially developed for use in laboratories, biotechnology and the healthcare sector. With its precise temperature control and robust design, it offers a reliable solution for storing sensitive samples and materials. Compared to similar products such as the Liebherr LGPv 6520 MediLine freezer, the LKPv 6527 is characterized by its versatility and high energy efficiency.
Technical details and functions
The Liebherr LKPv 6527 MediLine laboratory refrigerator offers a wide range of functions that make it an ideal choice for demanding applications:
-
Precise temperature control: the electronic control allows precise temperature adjustment to 1/10°C, which is particularly important for storing sensitive samples.
-
Ample space: with a gross capacity of 598 liters and four adjustable shelves, the refrigerator provides ample space for a variety of materials.
-
Robust construction: The housing is made of high-quality steel, while the interior is made of chrome-nickel steel, which ensures high durability and easy cleaning.
-
Energy efficiency: Energy consumption is around 688 kWh per year, which is very low compared to other appliances in this category.
-
Safety functions: The refrigerator is equipped with a visual and audible alarm system that is activated in the event of temperature deviations or open doors. In addition, a rechargeable battery takes over the power supply for up to 72 hours in the event of a power failure.
Certifications and standards
The Liebherr LKPv 6527 MediLine laboratory refrigerator complies with all relevant standards and certifications required for use in laboratories and the healthcare sector. These include, among others:
-
DIN 13277: This standard ensures that the refrigerator is suitable for the storage of medicines.
-
CE marking: The refrigerator complies with European safety, health and environmental protection requirements.
Application examples
The Liebherr LKPv 6527 MediLine laboratory refrigerator is versatile and suitable for various applications:
-
Laboratories: Ideal for storing chemicals, reagents and biological samples.
-
Biotechnology: Perfect for storing cell cultures and other sensitive materials.
-
Healthcare: Suitable for storing medicines and vaccines that require a constant temperature.
FAQs
How precise is the temperature control of the Liebherr LKPv 6527 MediLine laboratory refrigerator?
The refrigerator's electronic control system allows the temperature to be set precisely to 1/10°C, which ensures very precise control of the storage temperature.
What happens in the event of a power failure?
In the event of a power failure, a rechargeable battery takes over the power supply to the electronics for up to 72 hours. In addition, a visual and audible alarm signal is triggered to indicate the power failure.
How much space is available inside the refrigerator?
The Liebherr LKPv 6527 MediLine laboratory refrigerator offers a gross capacity of 598 liters and has four adjustable shelves made of plastic-coated grids.
What safety functions does the refrigerator offer?
The refrigerator is equipped with a visual and audible alarm system that is activated in the event of temperature deviations or open doors. In addition, an integrated data memory stores the minimum and maximum temperature values for up to 41 days.
Conclusion
The Liebherr LKPv 6527 MediLine laboratory refrigerator is an excellent choice for laboratories that require precise temperature control and high safety standards. With its large amount of space, robust construction and extensive safety features, it offers a reliable solution for storing sensitive materials. Similar products to the Liebherr LKPv 6523 MediLine laboratory refrigerator also offer high quality and reliability, but with different specifications and applications.
alarm: |
acoustical, optical |
Scope of application: |
multi-user refrigerator, commercial refrigerator, laboratory refrigerator, pharmaceutical refrigerator |
Series: |
MediLine |
Width (refrigerator): |
700 mm |
Width inside (refrigerator): |
533 mm |
Display: |
Digital display |
Noise level: |
58 dB (A) |
Glass door: |
without |
Height (refrigerator): |
2160 mm |
Height inside (refrigerator): |
1550 mm |
Refrigerant: |
R-290 |
Cooling capacity (gross): |
598 l |
Cooling technology: |
refrigerator |
Cooling (Cooling technology): |
dynamic (circulation cooling) |
Average consumption: |
1.885 kWh/24h |
Power consumption: |
2A |
Depth (refrigerator): |
830 mm |
Depth inside (refrigerator): |
650 mm |
Lowest temperature: |
+ 10°C |
lockable: |
yes (door) |
automatic defrost: |
with |
Explosion proof: |
no |
Shipping weight: |
155,00 kg
|
Item weight: |
129,00 kg
|
Liebherr laboratory refrigerator |
LKPv 6527 MediLine |
Gross / usable capacity |
598 l |
External dimensions WxDxH (mm) |
700 x 830 x 2160 |
Interior dimensions WxDxH (mm) |
533 x 650 x 1550 |
Energy consumption in 365 days1 |
688 kWh |
Ambient temperature |
+10 °C to +40 °C |
Refrigerant |
R 290 |
Sound power level |
58 dB(A) |
Voltage / connected load |
220 to 240V~ / 2.0 A |
Cooling system |
dynamic |
Defrosting method |
automatic |
Temperature range |
-2 °C to +16 °C |
Gradient2/ maximum fluctuation3 |
1.8 °C / 1.0 °C |
Housing material / colour |
Steel / white |
Door material |
Steel |
Inner container material |
Chrome-nickel steel |
Type of control |
electronic control |
Temperature display |
outside digital |
Mains failure alarm |
immediately in the event of a power failure for 72 hours |
Alarm in case of malfunction |
visual and audible |
Interface / potential-free contact |
RS 485 / yes |
Smart Cooling Hub |
prepared |
Interior lighting |
|
Adjustable shelves |
4 |
Usable width/depth of shelves (mm) |
533 / 650 |
Material of shelves |
Plastic-coated shelves |
Load capacity of shelf |
60 kg |
Castors |
Swivel castors with locking brake at front, fixed castors at rear |
Handle |
Handle strip |
Lock |
present |
Self-closing door |
yes |
Door hinge |
exchangeable on the right |
Gross / net weight |
155 / 129 kg |
Accessories |
|
Plastic-coated support shelf |
on request |
Support rail U-shape right |
on request |
Support rail U-shape left |
on request |
Foot pedal opener |
on request |
Converter with software (serial connection) |
on request |
NTC product temperature sensor |
on request |
Side-by-side set |
|
1 measured at +25 °C ambient temperature and set temperature of +5 °C for refrigerators and -20 °C for freezers.
2 Gradient according to EN60068-3: spatial temperature distribution in the interior of the warmest and coldest measuring point including measurement uncertainty.
3 Maximum fluctuation according to EN 60068-3: Temporal temperature variation of the measuring point with the greatest difference during the measuring period.
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde
There are no reviews yet.