Hellma Micro-Cuvette 115B-QS, 10 mm layer thickness
This high-quality cuvette enables precise absorption measurements in the most demanding laboratory environments. It offers exceptionally high optical quality, particularly for quantitative UV/VIS analyses in the pharmaceutical and biotechnology industries, thanks to its quartz glass with a working range of 200 nm to 2500 nm. The black side walls and base reduce disruptive reflections and scattered light, which facilitates even more accurate measurements. Compared to similar products on the market, the Hellma Micro-Cuvette 115B-QS, 10 mm layer thickness, stands out above all for its robust workmanship, its resistance to chemical cleaning agents, and the PTFE stopper supplied, which provides additional protection against unwanted contamination.
Maximum precision and durability
This microcuvette is specially designed for demanding measurements that require high signal stability and measurement accuracy. The quartz glass (QS) used ensures that reliable results can be achieved even in the ultraviolet and near-infrared wavelength range. At the same time, the high purity of the glass guarantees reliable light transmission and ensures reproducible results in research and routine laboratories. Its black surface on the side walls and bottom minimizes unwanted light reflections, which significantly increases accuracy in many photometry applications.
Beyond its external design, the Model 115B-QS impresses with the following technical features:
• Layer thickness: 10 mm for optimal light path length in typical UV/VIS analyses
• Volume: 400 µl, ideal for precious or limited samples
• External dimensions (H x W x D): 40 x 12.5 x 12.5 mm for a compact and compatible design
• Internal width: 2 mm for better concentration determination with low sample volumes
• Base thickness: 1.25 mm for reliable mechanical stability and uniform light transmission
• Material color code: QS (quartz glass with high transmission from 200 nm to 2500 nm)
• Number of windows: 2 to ensure precise light guidance in common spectrophotometers
The robust PTFE stopper prevents sample evaporation and protects against contamination. PTFE is characterized by its excellent chemical resistance, meaning that the material does not decompose or deform even when exposed to aggressive solvents. This keeps the sample chamber securely closed and allows the cuvette to be used even in volatile environments or for longer measurement series. The very fine inner width of 2 mm enables accurate measurements even with small sample quantities. Quality and safety standards play a crucial role in laboratory applications. Hellma manufactures cuvettes that meet the most stringent standards and guidelines in the field of optical measurement technology. This attention to detail results in products with excellent light transmission and the best possible cleaning options.
Specific application examples
• Protein quantification: The precise workmanship of this cuvette is particularly impressive when determining protein concentration with UV absorption in the range of 280 nm.
• Nucleic acid analysis: Thanks to the ultraviolet transmittance of quartz glass, measurements at 260 nm for DNA and RNA testing are easily possible.
• Clinical chemistry: Sensitive samples, such as those from enzyme studies or hormone analysis procedures, benefit from the small sample volume and high material purity.
• Pharmaceutical research: Substances such as buffer solutions, media, or active ingredient samples can be analyzed reproducibly at different wavelengths.
FAQs
How should the product be cleaned?
The cuvette can be rinsed with suitable laboratory cleaners or with diluted acid or ethanol. Finally, it is recommended to rinse with deionized water and dry in a dust-free environment.
What wavelengths does the quartz glass cover?
The QS quartz glass used is suitable for measurements in the range from 200 nm to 2500 nm. This means it can be used for UV, visible, and near-IR ranges.
Is the product scratch-resistant?
The quartz glass itself is very resistant. Nevertheless, users should avoid working with hard or abrasive objects in order to prevent scratches on the optically active surfaces.
Is the cuvette suitable for high-temperature measurements?
In general, quartz glass can withstand high temperatures. However, it is advisable to ensure controlled heating and avoid abrupt temperature changes so that material stress remains low.
Can aggressive solvents be used?
The PTFE stopper and chemical-resistant quartz glass make this cuvette very versatile. Nevertheless, it should always be checked in advance whether the respective solvent is compatible with quartz glass and PTFE.
Conclusion
This micro cuvette delivers precise, reproducible measurements across a wide spectrum and is therefore ideal for quality-relevant analyses in research, industry, and routine testing. Its compact shape, robust design, and minimized sample volume are particularly impressive in modern laboratories that value efficiency and reliability. Its chemical resistance and high optical quality ensure long-lasting, consistent results.