Hellma Macro Cell 109.000-QS, 10 mm layer thickness
The Hellma Macro Cell 109.000-QS, 10 mm layer thickness, is specially designed to perform high-precision absorption measurements in laboratory environments. With its robust quartz glass covering a wavelength range from 200 nm to 2500 nm, this cuvette is particularly suitable for UV/VIS analyses. Thanks to its sophisticated design with sufficient space for a magnetic stirring bar and the standardized 10 mm light path, it is often the first choice when it comes to precise and repeatable measurement results.
Versatile solution for demanding laboratory analyses
This cuvette was developed by Hellma to cover a wide range of applications in chemical, biotechnological, and pharmaceutical laboratories. It is designed for maximum accuracy and complies with all aspects of Lambert-Beer's law for photometric measurements. The product is also equipped with a PTFE (polytetrafluoroethylene) hinged lid to protect samples from contamination or evaporation. At the same time, the lid is easy to handle and ensures a secure seal throughout the entire analysis process. Below is a compact overview of important technical data:
• Type: 109.000-QS
• Material: Quartz glass covering the spectrum from 200 nm to 2500 nm
• Layer thickness: 10 mm
• Volume: 3500 µl
• External dimensions (H x W x D): 45 x 12.5 x 12.5 mm
• Internal width: 9.5 mm
• Number of windows: 2
• Base thickness: 5 mm
Thanks to its large sample volume (up to 3.5 ml), this macro cuvette is ideal for measuring both aqueous and organic samples. Its user-friendly external dimensions also allow it to be placed securely in the spectrophotometer without compromising the accurate adjustment for optical measurement. Thanks to its two optical windows, it also enables reliable transmitted light measurements. Quartz glass is a durable material that impresses with its high transparency across the entire UV/VIS range, among other things. This makes the cuvette a universally applicable laboratory tool that is suitable for numerous applications in the field of spectroscopy. The quality of the cuvette is particularly important in analyses involving sensitive substances such as proteins, nucleic acids, or certain dyes. The quartz quality used here ensures that disruptive reflections or scattering losses are minimized to a large extent.
In addition, the special PTFE folded lid is practically insensitive to many aggressive chemicals and ensures a tight seal, reducing the risk of evaporation or contamination of the sample. This is particularly important when volatile solvents such as acetonitrile, methanol, or chloroform are used. Likewise, many bioactive molecules, such as enzymes or antibodies, can be handled safely without the cuvette absorbing or contaminating additional reagents. In terms of certifications and standards, it can be assumed that the high-quality quartz glass complies with the relevant laboratory standards and that the macro cuvette is approved for a wide range of international methods. For laboratories working according to GLP (Good Laboratory Practice) or DIN standards, it is therefore a reliable component in daily workflows.
Specific application examples
- Quantitative analysis of DNA and RNA in the UV range, especially in the spectral range around 260 nm.
- Measurement of protein solutions at 280 nm to determine protein concentration.
- Determination of low dye concentrations, for example in environmental analysis for the detection of dyes in drinking water.
- Photometric analysis of volatile substances in organic solvents.
FAQ
What is the best way to clean this cuvette?
Cleaning should generally be carried out using a suitable cleaning agent and then deionized water. For stubborn residues, a dilution of hydrochloric acid or alkaline cleaners can be used, provided that the quartz glass is not damaged.
Can the cuvette also be used for fluorescence measurements?
Since it is made of quartz glass, it can generally be used for fluorescence measurements. However, it should be noted that there are only two windows and, depending on the measurement setup, a different geometry may be required.
Which stirring bars fit in the cuvette?
The inner width of 9.5 mm allows the use of smaller magnetic stirring bars, which are usually between 8 and 9 mm long. This provides sufficient space to mix the sample homogeneously.
What should you pay attention to when filling?
Be careful not to overfill the macro cuvette. A maximum volume of 3.5 ml should not be exceeded to avoid contamination of the lid or the spectrophotometer.
Conclusion
This macro cuvette combines the advantages of high-quality quartz glass with a user-friendly design that enables stable, repeatable measurement. Thanks to its generous internal dimensions, samples can be varied in many ways, while the PTFE lid ensures a secure seal. Whether for DNA and protein determinations or the analysis of volatile solvents, this cuvette is a reliable choice when maximum precision and long service life are required.