Hellma Macro Cell 100-QS, 40 mm layer thickness
The Hellma Macro Cell 100-QS, 40 mm layer thickness, enables precise absorption measurements across a wide wavelength range and is specially designed for demanding photometric applications. Anyone who needs a high-quality cuvette for a wide range of analytical tasks in laboratory environments will benefit from the unique combination of precise workmanship, robust quartz glass, and a well-thought-out design. Compared to conventional cuvettes, this model scores particularly highly thanks to its high optical quality and durable construction, which ensures the best possible measurement results even with frequent use.
Performance characteristics and special features
Thanks to its 40 mm layer thickness and special 100-QS design, this cuvette delivers particularly reliable results in UV and VIS spectra. The quartz glass used covers a spectral range from 200 nm to 2500 nm, enabling a wide range of applications for quantitative analysis. A PTFE hinged lid also provides protection against contamination and ensures a consistent seal. This makes the cuvette ideal for a wide range of laboratory applications, such as in biochemical or chemical research.
Important technical features at a glance: • Material: Quartz glass (QS) for 200 nm – 2500 nm
• Layer thickness: 40 mm (ideal for macro analyses)
• Volume: 14,000 µl for larger sample quantities
• External dimensions (H × W × D): 45 × 12.5 × 42.5 mm
• PTFE hinged lid for reliable sealing
• Two windows for precise transmitted light measurements
• DIN and ISO-compliant manufacturing for reproducible results
In addition, the resistance of the quartz glass used offers an important advantage for laboratories where aggressive substances are used. The material retains its optical properties even under thermal and chemical stress. Also particularly noteworthy is the rebated lid, which is made of PTFE (polytetrafluoroethylene) and is characterized by outstanding chemical resistance. This reliably protects the sample from harmful environmental influences during measurement.
The high precision in manufacturing results in exceptionally low tolerances, which promotes accurate and reproducible measurement results. This is a decisive advantage, especially for investigations in the pharmaceutical industry, quality control, or research institutes. Thanks to the generous sample volume of 14,000 µl, even viscous or complex samples can be handled easily.
Certifications and standards
Hellma ensures that all cuvettes are manufactured to strict standards. Corresponding DIN and ISO certifications attest to consistent high quality and serve as a guarantee for reliable measurement results. Especially in sensitive measurement areas such as UV/Vis spectroscopy, fully documented manufacturing processes are necessary to meet the high demands of modern laboratories.
Specific application examples
• Analysis of nucleic acid-containing solutions (e.g., DNA quantification at 260 nm) for diagnostic purposes in clinical laboratories.
• Determination of protein concentration in the UV range, for example, after Bradford assays or Lowry assays, for research and quality control.
• Determination of dye or pigment concentrations in industrial applications, e.g., in the textile or paint industry.
• Photometric measurements of enzyme activities in biochemical laboratories for the investigation of metabolic processes.
The Hellma Macro Cuvette 100-QS, 40 mm layer thickness, can be used equally well for analytical investigations in the food industry, in process and environmental analysis, and in R&D departments when the spectrum from 200 nm to 2500 nm needs to be covered.
FAQs
What is the best way to clean the cuvette?
After each measurement, first rinse the cuvette with a suitable solvent or detergent (e.g., deionized water or acetone, depending on the substance). Be sure not to use any abrasive materials to protect the surface of the quartz glass.
Can I use the cuvette at higher temperatures?
Quartz glass is characterized by excellent temperature resistance. Nevertheless, the cuvette should not be exposed to extreme temperature fluctuations, as this could cause fine stress cracks in the material.
Which samples are suitable for this model?
Liquid samples in UV/Vis spectroscopy are particularly ideal. Thanks to the high chemical resistance of the PTFE lid, even highly reactive samples can be analyzed without contamination.
Is the cuvette suitable for simultaneous photometry of multiple wavelengths?
Yes, the quartz glass allows measurement of a broad wavelength spectrum from 200 nm to 2500 nm. This makes the cuvette suitable for multi-wavelength measurements, which are frequently used in modern laboratories.
Conclusion
Its robust construction, wide wavelength spectrum coverage, and easy handling make this macro cuvette an excellent tool for high-precision analyses. Laboratory technicians who handle larger sample volumes or need to perform demanding measurements in the UV to near-infrared range will particularly benefit from its durable and reliable results. Thanks to its practical PTFE hinged lid design and extremely solid quartz glass construction, this model meets all the requirements of a high-quality laboratory cuvette.