Hellma Macro Cell 100-OS, 5 mm layer thickness
The Hellma Macro Cuvette 100-OS, 5 mm layer thickness, is designed for precise absorption measurements in the UV-VIS range and impresses with its special optical glass, which covers a broad wavelength spectrum from 320 nm to 2500 nm. Laboratory users benefit from excellent light transmission and accurate measurement results, especially when it comes to demanding photometric analyses. Compared to other cuvettes on the market, this model scores points for its durable design and specially adapted shape, which makes it comfortable to handle. The PTFE (polytetrafluoroethylene) hinged lid ensures a reliable seal, protecting samples even in the most sensitive applications.
Versatile features and technical details
This cuvette is designed for long-term durability and consistently high measurement accuracy. The OS glass used is capable of ensuring light transmission even in the short-wave UV range, while at the same time delivering reliable results in the visible and near-infrared range. The combination of light transmission and chemical resistance is a decisive advantage for laboratory environments where samples from a wide variety of substances are examined.
Important technical data at a glance: • Type: 100-OS
• Material color code: OS (special optical glass 320 nm – 2500 nm)
• Layer thickness: 5 mm
• Volume: 1750 µl
• External dimensions (H x W x D): 45 x 12.5 x 7.5 mm
• Internal width: 9.5 mm
• Base thickness: 1.5 mm
• Number of windows: 2
Thanks to this design, the product can be easily used in various spectrometers. The large window areas facilitate the incidence of the light beam and ensure that measurements can be carried out reliably even with small sample volumes. The capacity of 1750 µl allows for optimal sample preparation without using unnecessary amounts of material. Laboratories that perform both routine and specialized analyses benefit particularly from this cuvette, as it is resistant to numerous solvents and is suitable for high-precision measurements.
The PTFE hinged lid also provides a reliable seal. PTFE is chemically inert and therefore ideal for preventing unwanted contact between the sample and the environment. The robust housing, measuring 45 x 12.5 x 7.5 mm, allows the cuvette to be used both stationary in spectrophotometers and in automated analysis systems without compromising precision or durability.
Certifications and standards
Manufacturers such as Hellma attach great importance to the quality and precision of their products. In this model, manufacturing under ISO-compliant conditions (e.g., quality management according to DIN EN ISO 9001) ensures consistent quality. In addition, the cuvette can be used in accordance with various national and international standards for optical measurement methods, which is particularly important in accredited laboratories.
Specific application examples
• Quantitative analysis of biological samples: This cuvette is suitable for enzyme tests and protein concentration determinations, as the OS glass allows for a wide measuring range.
• Photometric determination of heavy metals: Its high resistance to aggressive chemicals is particularly evident in tests involving aqueous solutions.
• Testing of UV-absorbing additives: In the plastics industry, additives can be tested for their effectiveness.
• Analysis of proteins or nucleic acids: In biochemical laboratories, the cuvette is an important instrument for the accurate determination of DNA, RNA, and protein concentrations.
FAQs
What is the best way to clean the cuvette?
Cleaning is recommended with suitable, non-abrasive solutions that are compatible with the properties of PTFE and special optical glass. In most cases, rinsing with deionized water or mildly alkaline cleaners is sufficient.
Can corrosive chemicals be used?
Thanks to the chemically resistant PTFE lid material and OS glass, the cuvette is robust enough for many aggressive substances. However, in the case of highly concentrated acids or bases, it should always be checked whether the glass or seal could be damaged.
Which spectrometer is compatible with the cuvette?
The standardized external dimensions allow universal use in most common spectrometers. Whether UV-VIS or NIR, the product is flexibly adaptable and highly compatible.
Is calibration necessary?
Calibration of the cuvette itself is not necessary. However, the spectrometer should be calibrated regularly using suitable reference standards to ensure correct measurements.
Conclusion
With its high light transmission, precision-machined OS glass, and chemical resistance, this cuvette is an essential component for demanding absorption-based analyses. The combination of stable construction, reliable sealing thanks to the PTFE hinged lid, and convenient handling makes it the ideal companion in many laboratory areas. Thanks to its broad compatibility in the spectral range from 320 nm to 2500 nm, routine and special analyses can be performed with equal precision, ensuring consistent and reproducible results. Manufactured to high quality standards, this solution has proven itself to be a durable instrument that represents an excellent investment for all users in the field of photometric measurements.