Hellma Macro Cuvette 100-OS, 2 mm layer thickness
The Hellma Macro Cuvette 100-OS, 2 mm layer thickness, was specially developed for precise absorption measurements in the laboratory. Thanks to its high-quality manufacturing and the use of special optical glass, it proves reliable in demanding applications. Compared to similar cuvettes on the market, this model offers high measurement accuracy, a robust structure, and the ability to process even the smallest sample volumes with exact results.
Precise cuvette for laboratory applications
This cuvette model is designed for use in various industries, particularly in the chemical and pharmaceutical industries and in scientific laboratories that perform UV/Vis analyses. The special material composition allows measurements in a wide wavelength range from 320 nm to 2500 nm. This enables efficient use in spectroscopy, for example to determine concentrations and absorption spectra in proteins, DNA samples, or other substances.
Important features at a glance:
• Material: Special optical glass (OS) for measurements between 320 nm and 2500 nm
• Layer thickness: 2 mm, optimized for precise measurements with low volumes
• Volume: 700 µl, ideal for economical use of expensive or limited samples
• Lid: PTFE hinged lid with additional glass cover plate
• External dimensions: 45 mm height, 12.5 mm width, 4.5 mm depth – compact dimensions that fit into many devices
• Number of windows: 2, allowing measurements from two directions
• Solid base thickness: 1.5 mm for reliable stability In addition, the specially designed inner width of 9.5 mm ensures that samples can be distributed homogeneously in a confined space. For precise, reproducible results, great attention is paid to manufacturing tolerances so that each cuvette offers the same optical path and volume. Solid manufacturing with optically polished surfaces makes this cuvette a reliable component in analytical laboratories.
Certifications and standards
Hellma is known for its high quality standards. Cuvettes such as these are often subject to strict production standards, such as ISO 9001. Strict compliance with this standard supports consistently high quality and measurement reliability. In addition, the special optical glass is suitable for the wavelength ranges commonly used in many laboratories and thus meets important requirements in terms of accuracy and consistency.
Application examples in everyday laboratory work
• Quantitative analysis of protein concentrations: Thanks to the wide wavelength range and low layer thickness, proteins (e.g., BSA) can be measured precisely.
• DNA and RNA determinations: When using nucleic acids, the 2 mm layer thickness and high-quality glass properties enable clear and stable signal detection.
• Photometric concentration measurements: Whether in the organic or inorganic field, the cuvette is versatile, for example in color or turbidity measurements.
• Special pharmaceutical analysis: The cuvette is suitable for testing active ingredient concentrations in medications thanks to its reproducible parameters and the durability of the special optical glass.
In all applications, the robust design guarantees a stable fit in the photometer, while the PTFE hinged lid system with glass cover minimizes the ingress of dirt or evaporation losses. The small layer thickness of only 2 mm is an advantage when it comes to saving sample material or measuring particularly concentrated substances.
FAQs
What are the advantages of the PTFE hinged lid?
The PTFE hinged lid is chemically inert, so there is no risk of residue or contamination. At the same time, it is easy to clean and, when used in combination with the glass cover, provides a tight seal for sensitive samples.
Is a special cleaning procedure required?
For most applications, cleaning can be carried out using standard laboratory rinsing solutions such as pepsin solution or weak acids. Be sure to rinse thoroughly with distilled water afterwards to avoid residues.
Which spectrometers are compatible?
As a rule, all common spectrometer models or photometers designed for 12.5 mm wide cuvette holders can be used with this cuvette. Consult your device's data sheet in advance to ensure that the insertion dimensions are compatible.
How sensitive is the material to chemicals?
The special optical glass (OS) is highly resistant to numerous laboratory reagents. In the case of particularly hot, corrosive, or aggressive chemicals, it is advisable to check compatibility in advance to avoid damage to the glass.
Conclusion
The cuvette presented here offers an extremely reliable and durable solution for users working in the field of spectroscopy and photometry. Its wide wavelength range, special optical glass, low coating thickness, and secure PTFE hinged lid make it the first choice for precise analyses in a wide variety of laboratory segments. Professionals benefit from a stable design, practical dimensions, and a well-thought-out construction that reliably supports measurement accuracy and repeatability.