Hellma Large Cell 704.003-OG, 50 mm layer thickness
This cell has been specially developed for laboratories and research areas that require high precision and first-class material quality for spectroscopic applications and microscopic examinations. Its high-quality optical glass and spacious interior make it ideal for experiments that require a larger sample volume or a longer layer thickness. Compared to many standard cuvettes on the market, it impresses with its extremely precise manufacturing, durable construction, and excellent light transmission across a wide wavelength range. Those looking for reliable and robust cuvettes for demanding tasks therefore often turn to this model. High-quality features and precise workmanship Thanks to its manufacture from special optical glass (color code OG), measurements can be carried out in the wavelength spectrum from approximately 360 nm to 2500 nm. This enables a very wide range of applications, from UV-sensitive samples to the visible range and near-infrared. The generously dimensioned interior allows sample volumes of up to 88,000 µl. This means that samples with higher particle concentrations or samples with low absorption can be examined accurately and with repeatable precision.
Another unique feature is the stable construction with identical internal and external dimensions (50 x 50 x 50 mm inside, 52.5 x 55 x 55 mm outside), which supports easy handling. The glass lid included in the scope of delivery can provide additional safety, especially when working with sensitive samples. It prevents contamination and reduces the risk of evaporation or unwanted introduction of foreign substances. In addition, this lid allows samples to be observed or incubated over longer periods of time without affecting important parameters.
The relatively long layer thickness of 50 mm (tolerance ± 0.5 mm) ensures that even samples with a low absorption spectrum can be reliably detected. At the same time, this also allows precise optical measurements to be carried out over a wider depth range. This is a crucial prerequisite for accurate data recording, especially in demanding color measurements and spectroscopic procedures. This large cuvette is often used in laboratories for chemical and biotechnological investigations, for example in the analysis of protein solutions, nucleic acids, cell cultures, or water samples. The main highlights can be summarized as follows: • Type 704.003-OG
• Material: Optical glass for 360 nm to 2500 nm
• Volume: 88000 µl
• Layer thickness: 50 mm (± 0.5 mm)
• External dimensions (H x W x D): 52.5 x 55 x 55 mm
• Internal dimensions (H x W x D): 50 x 50 x 50 mm
• Includes glass lid for additional safety
The cuvette is manufactured in accordance with strict quality standards, meaning that it is subject to quality criteria in line with common standards such as DIN ISO 9001. Due to its transparent and scratch-resistant properties, the cuvette can also be cleaned regularly and does not require excessive care. The optical glass remains resistant to many laboratory chemicals and can be used in different pH ranges. However, for the longest possible service life, cleaning according to the manufacturer's instructions and careful, dust-free storage are recommended.
Practical application examples
• Color and turbidity measurements in water analysis: Thanks to the large layer thickness of 50 mm, even minimal color nuances in water or environmental samples can be detected.
• Analysis of proteins and nucleic acids: The high optical quality and wide transmission spectrum allow precise photometric determination of biomolecules.
• Microscopic observations of living cells: The glass cover supplied can be used to seal the sample, reducing contamination and minimizing evaporation.
• Quality control in industry: Whether paints, plastics, or other chemicals—a reliable cuvette is indispensable for color measurements and spectroscopic analyses.
Frequently asked questions (FAQ)
What is the best way to clean the cuvette?
Manual cleaning with mild detergents and deionized water is sufficient. For stubborn residues, special cleaning solutions recommended by the manufacturer can be used.
Can it be used with aggressive chemicals?
Thanks to its optical glass, the cuvette is highly resistant to many acids, bases, and solvents. Nevertheless, corrosive reactions should be checked individually and compatibility should always be clarified in each individual case.
Is temperature control possible?
Temperature control is possible if the measuring system or peripheral devices used have a control function. The cuvette itself conducts heat evenly, so a temperature chamber can be used if necessary.
Is the model only suitable for spectroscopic investigations?
In addition to spectroscopy, this model is also successfully used for microbiological assays or observations under a microscope. It offers a flexible solution for a wide range of applications in chemistry, biology, and materials research.
Conclusion
The large cuvette with a layer thickness of 50 mm and optical glass material is a reliable choice for demanding analytical and microscopic work. Its spacious volume, robust dimensions, and high transmission make it versatile, from classic color measurements to the detection of the lowest concentrations in complex sample systems. Thanks to its durable construction, it can also be used long-term in high-traffic laboratory environments. Anyone looking for a high-quality cuvette for large-volume or sensitive samples will particularly benefit from this durable, precisely manufactured laboratory solution.