Hellma Compact Cell 178.710-OS, 10 mm SD/15 mm ZH
The Hellma Compact Cell 178.710-OS is characterized by its precise workmanship in special optical glass, which covers a wide wavelength range from 320 nm to 2500 nm. This measuring system is very popular with laboratory professionals who want reliable and repeatable flow or absorption measurements. Thanks to its outstanding quality and easy integration into various device environments, this cuvette is a powerful solution for demanding measurement tasks.
Performance characteristics and design
This model focuses on ease of use combined with high optical purity. Its specially developed design ensures optimal alignment in the beam path. The compact format offers a small footprint in the laboratory and facilitates installation in automated systems. At the same time, the special optical glass minimizes potential measurement errors and ensures consistently high transmission in the relevant wavelength range.
The cuvette has two screw connections (M 6 x 1) that can be connected to the FEP tubing supplied. FEP (fluoroethylene propylene) has excellent chemical resistance and is suitable for a wide range of samples, solvents, and reagents. In addition, the tube length of 500 mm allows for flexible arrangement in the test stand or measurement setup. This makes it easy to perform both continuity measurements and simple flow measurements. Technical data at a glance Layer thickness: 10 mm Center height: 15 mm
• Volume: 80 µl
• Outer housing dimensions (H x W x D): 35 x 12.5 x 12.5 mm
• Aperture diameter: 3 mm
• Material: Special optical glass (320 nm – 2500 nm)
• Connections: 2 x M 6 x 1 with FEP tubes
The glass is selected as a special optical material to ensure distortion-free transmission of the light beam. The aperture diameter of 3 mm ensures reliable detection of the beam, while the layer thickness of 10 mm provides a universally applicable geometric basis for many applications. Thanks to the low cuvette volume of 80 µl, valuable sample material can be saved. All these factors simplify everyday laboratory work and make the system ideal for analysis procedures that require reproducible and accurate results.
The manufacturing quality is based on established standards in optical measurement technology. If required, this cuvette can be used in accordance with industry guidelines for DIN/ISO-specific applications. Especially in combination with quality-tested spectrometers and calibration materials, this design facilitates compliance with demanding validation criteria.
Application examples
The areas of application cover a wide range of sectors and extend from everyday laboratory work to specialized testing processes:
• Photometric determination of nutrient content in food
• Continuous monitoring of fermentation processes in biotechnology plants
• Testing of polymer monomers in the plastics industry
• Characterization of dye solutions in the textile and printing industry
In addition, samples such as ethanol, methanol, acetic acid, or saline buffer solutions can be measured safely and without residue thanks to the chemical resistance of the FEP tubing. When testing light-sensitive substances, the high-quality glass ensures precise absorption values without disruptive reflections.
FAQs
How is the cuvette cleaned correctly?
For routine cleaning, a mild detergent and distilled water are often sufficient. For stubborn residues, a suitable cleaning agent for optical components or a weak acid can also be used. Then rinse thoroughly with clean water and blow dry.
Which substances can be measured safely?
Thanks to the robust special glass and FEP tubing, the system is suitable for many aqueous solutions, organic solvents, and even slightly aggressive chemicals. Only highly concentrated acids or strong bases should be tested for compatibility in advance.
How long do the FEP tubing last?
Under normal laboratory conditions and when used properly, the tubing is extremely durable. FEP exhibits high resistance even at temperatures up to approximately 200 °C. Nevertheless, regular visual inspection is recommended in order to detect possible damage in good time.
Can the system be integrated into automated laboratory processes?
Yes, the standardized connections and compact design allow for easy integration into automated flow measurements or robot-assisted analytical systems. It is only important to ensure a secure and tight connection.
Conclusion
The compact cuvette presented here offers a sophisticated combination of stability, precision, and chemical resistance. Thanks to its robust construction, minimal sample volume, and flexible connection options, it is ideal for both freehand measurements and automated environments. Users thus receive a durable, high-quality cuvette that opens up a wide range of applications in analysis, quality assurance, and research. This allows both routine flow measurements and precise absorption analysis to be carried out in a wide range of laboratory applications.