The Dräger X-plore 7300 is a state of the art blower filter device specifically designed to protect against harmful substances, particles, bacteria and pathogens. This device is ideal for use in laboratories, the chemical industry and other environments where a high standard of protection is required. Thanks to its robust construction and high-quality coating, the X-plore 7300 offers reliable protection for your personnel. Compared to similar products such as the Dräger X-plore 7500, the X-plore 7300 is characterized by its variable air delivery rate and long service life.
Technical data and features
The Dräger X-plore 7300 offers a wide range of technical features that make it an excellent choice for professional use:
-
Protection classes: TH1, TH2, TH3, TM1, TM2, TM3
-
TH1: Protection up to 5 times the limit value, not suitable for carcinogenic, very toxic and radioactive gases and vapors as well as biological agents in risk groups 2 and 3.
-
TH2: Protection up to 20 times the limit value.
-
TH3: Protection up to 100 times the limit value.
-
TM1: Protection up to 10 times the limit value, not suitable for radioactive gases and vapors.
-
TM2: Protection up to 100 times the limit value.
-
TM3: Protection up to 500 times the limit value.
Approvals: EN 12941 (with Dräger X-plore helmets, hoods and visors), EN 12942 (with Dräger X-plore 4740 / 6000 half and full face masks)
Air delivery rate: Variably adjustable from 140 to 210 l/min
Battery technology: NiMH battery 4.8 V / 4.5 Ah, individual charger with overcharge protection
Weight: 900 g (incl. filter and battery)
Filter class: TH3 P SL R (with Dräger X-plore helmets, hoods and visors), TM3 P SL R (with Dräger X-plore 4740 / 6000 half and full face masks)
Duration of use: 6 to 15 hours (depending on the set air delivery rate and the concentration of pollutants)
MarkingP: Protection against particles
SL marking (Solid & Liquid): Can be used against aerosols
MarkingR: Suitable for use over several work shifts
Certifications and standards
The Dräger X-plore 7300 meets the stringent requirements of the EN 12941 and EN 12942 standards, making it a safe choice for professional use. These certifications ensure that the device works reliably under various conditions and meets the highest safety standards.
Application examples
The Dräger X-plore 7300 is versatile and particularly suitable for the following applications:
-
Laboratories: protection against chemical vapors, particles and biological agents.
-
Chemical industry: Protection against hazardous gases and vapors.
-
Pharmaceutical industry: Protection against aerosols and particles during the production and processing of medicines.
-
Construction industry: protection against dust and other particles on construction sites.
FAQs
How long does the battery of the Dräger X-plore 7300 last?
The battery lasts between 6 and 15 hours, depending on the set air delivery rate and pollutant concentration.
Can the Dräger X-plore 7300 be used against radioactive gases?
Class TM1 devices may not be used against radioactive gases and vapors. However, it can be used for other classes such as TM2 and TM3.
Which filter classes are compatible with the Dräger X-plore 7300?
The Dräger X-plore 7300 is compatible with filter classes TH3 P SL R and TM3 P SL R, depending on the mask or hood used.
Conclusion
The Dräger X-plore 7300 is a powerful and versatile blower filter device that is characterized by its high level of protection and long service life. With its numerous certifications and the ability to adjust the air delivery rate variably, it offers reliable protection in various industrial and laboratory applications. Similar products such as the Dräger X-plore 3300 or the Dräger Oxy 3000 MK II also offer high safety standards and can be a good alternative depending on specific requirements.
Protective equipment: |
powered air purifying respirator |
Shipping weight: |
0,86 kg
|
Item weight: |
0,86 kg
|
LIMITS OF USE
|
protection class |
multiple 1) the limit 2)
|
limitations of use |
TH1 |
5 |
Devices of class TH1 may not violate carcinogenic, very toxic and radioactive gases and vapors and airborne biological agents of risk groups 2 and 3 and enzymes are used |
TH2 |
20 |
- |
TH3 |
100 |
- |
TM1 |
10 |
A Class TM1 may not be used against radioactive gases and vapors |
TM2 |
100 |
- |
TM3 |
500 |
- |
1) - According to EN 529:2005 possible, changes by national regulations.
2) - Set country-specific, maximum to exceed the exposure limit value with respiratory protective equipment.
SPECIFICATIONS
|
Approvals |
EN 12941 (with Dräger X-plore helmets, hoods and visors) EN 12942 (with Dräger X-plore 4740/6000 Half and Full Face Masks) |
Air delivery |
adjustable 140-210 l / min |
Battery technology |
NiMH battery 4,8 V / 4,5 Ah, single charger with overcharge protection |
Weight |
900 g (Blower unit including filter and battery) |
filter class |
TH3 P SL R (with Dräger X-plore helmets, hoods and visors) TM3 P SL R (with Dräger X-plore 4740/6000 Half and Full Face Masks) |
period of use |
6 - 15 hours (depending on the set of the air delivery and the pollutant concentration) |
marking P |
to protect against particles |
marking SL (Solid & Liquid) |
used against aerosols |
marking R |
suitable for use over several shifts |