Dräger X-am 2500
The Dräger X-am 2500 is a versatile and robust gas detector specially developed for use in industry, mining and refineries. It provides reliable monitoring of hazardous gases and ensures maximum safety in potentially explosive atmospheres. Thanks to its durable sensors and the ability to operate in both diffusion and pump mode, the Dräger X-am 2500 is a preferred choice for professionals who require the highest precision and reliability. Similar to the Dräger X-plore 7500, the X-am 2500 offers high durability and longevity.
Technical data and functions
The Dräger X-am 2500 is equipped with various sensors that can monitor a wide range of gases:
-
EX sensor:
- Measuring range: 0 - 100 % LEL, 0 - 5 vol.% CH₄
- Resolution: 1 % LEL
- Response time (t₉₀): 10 seconds
- Service life: > 4 years
-
O₂ sensor:
- Measuring range: 0 - 25 % by volume
- Resolution: 0.1 % by volume
- Response time (t₉₀): 10 seconds
- Service life: > 5 years
-
CO sensor:
- Measuring range: 0 - 2,000 ppm
- Resolution: 2 ppm
- Response time (t₉₀): 15 seconds
- Service life: > 5 years
-
H₂S-LC sensor:
- Measuring range: 0 - 100 ppm
- Resolution: 0.1 ppm
- Response time (t₉₀): 15 seconds
- Service life: > 5 years
-
SO₂ sensor:
- Measuring range: 0 - 100 ppm
- Resolution: 0.1 ppm
- Response time (t₉₀): 15 seconds
- Service life: > 3 years
-
NO₂ sensor:
- Measuring range: 0 - 50 ppm
- Resolution: 0.1 ppm
- Response time (t₉₀): 15 seconds
- Service life: > 3 years
The device is compact and lightweight (220 - 250 g) and offers a high protection class (IP 67), making it waterproof and dustproof. It can be operated at temperatures from -20 to +50 °C and a pressure of 700 to 1300 mbar. The relative humidity can be between 10 and 95 %.
Certifications and standards
The Dräger X-am 2500 complies with numerous international standards and certifications, including
-
ATEX: I M1 Ex ia I Ma, II 1G Ex ia IIC T3 Ga, I M2 Ex d ia I Mb, II 2G Ex d ia IIC T4/T3 Gb
-
EN 50104: O₂
-
EN 45544: CO & H₂S
-
EN 60079-29-1: Methane to nonane
-
EN 50271: Software and documentation
-
CSA (Canada & USA): Class I Div. 1 Group A, B, C, D T.-Code T4/T3, A/Ex ia IIC T3 /Ga, A/Ex d ia IIC T4/T3 /Gb
-
IECEx: Ex ia I Ma, Ex ia IIC T3 Ga, Ex d ia I Mb, Ex d ia IIC T4/T3 Gb
-
CE mark: Electromagnetic compatibility (Directive 2004/108/EC); ATEX (Directive 94/9/EC)
-
MED: Marine Equipment Directive (Directive 96/98/EC)
Application examples
The Dräger X-am 2500 is ideal for various applications:
-
Industry: monitoring CO, H₂S, O₂, SO₂ and NO₂ in production facilities.
-
Mining: Ensuring air quality and monitoring methane and other combustible gases.
-
Refineries: Monitoring hydrogen sulphide and other hazardous gases.
FAQs
How long does the battery of the Dräger X-am 2500 last?
The device can be operated with alkaline batteries or rechargeable NiMH batteries. The operating time is more than 12 hours, with a high capacity battery even more than 13 hours. Without the Ex sensor, the operating time is typically more than 250 hours.
Can the Dräger X-am 2500 be used in hazardous areas?
Yes, the device has Ex approval for Zone 0 and is therefore suitable for use in potentially explosive atmospheres.
How do I switch between diffusion and pump operation?
Switching is quick and easy without tools or screws. The pump function starts automatically when the measuring device is inserted.
Conclusion
The Dräger X-am 2500 is a reliable and versatile gas detector that is characterized by its long-life sensors, high level of safety and ease of use. It is ideal for use in industry, mining and refineries and offers reliable monitoring of hazardous gases. Similar to the Dräger X-plore 3300, the X-am 2500 offers high durability and longevity.
|
Dräger X-am® 2500 |
|
|
sensors |
EX |
Measuring range |
0 - 100 % LEL 0 - 5 Vol.-% CH4
|
Resolution |
1 % LEL |
Response time (t90) |
10 Sec. |
Expected service life |
> 4 years |
|
|
sensors |
O2 |
Measuring range |
0 - 25 Vol.-% |
Resolution |
0,1 Vol.-% |
Response time (t90) |
10 Sec. |
Expected service life |
> 5 years |
|
|
sensors |
CO |
Measuring range |
0 - 2.000 ppm |
Resolution |
2 ppm |
Response time (t90) |
15 Sec. |
Expected service life |
> 5 years |
|
|
sensors |
H2S-LC |
Measuring range |
0 - 100 ppm |
Resolution |
0,1 ppm |
Response time (t90) |
15 Sec. |
Expected service life |
> 5 years |
|
|
sensors |
SO2 |
Measuring range |
0 - 100 ppm |
Resolution |
0,1 ppm |
Response time (t90) |
15 Sec. |
Expected service life |
> 3 years |
|
|
sensors |
NO2 |
Measuring range |
0 - 50 ppm |
Resolution |
0,1 ppm |
Response time (t90) |
15 Sec. |
Expected service life |
> 3 years |
|
|
Dimensions (W x H x D) |
48 x 130 x 44 mm |
Weight |
220 - 250 g |
Ambient conditions |
|
Temperature |
- 20 bis + 50 °C |
Pressure |
700 bis 1300 mbar |
Relative humidity |
10 bis 95 % r. H. |
Protection class |
IP 67 |
Alarms |
|
Visual |
360 ° |
Audible |
Multi-tone > 90 dB at 30 cm |
Vibration |
|
Operating times |
> 12 h with alkaline and NiMH > 13 h with NiMH HC, > 250 h w/o Ex sensor with alkaline batteries |
Charging time |
< 4 h |
Datalogger |
Retrievable using an infrared interface > 1000 h with 4 gases at a recording interval of 1 value per minute |
Default setting Calibration interval1
|
122 days (4 month) |
Approvals |
|
ATEX |
I M1 Ex ia I Ma, II 1G Ex ia IIC T3 Ga, I M2 Ex d ia I Mb, II 2G Ex d ia IIC T4/T3 Gb |
Performance approval to: |
EN 50104(2002)+A1(2004): O2 EN 45544: CO & H2S EN 60079-29-1:2007: Methane to nonane EN 50271:2001: Software and documentation |
CSA (Kanada & USA) |
Class I Div. 1 Group A, B, C, D T.-Code T4/T3 A/Ex ia IIC T3 /Ga A/Ex d ia IIC T4/T3 /Gb |
IECEx |
Ex ia I Ma Ex ia IIC T3 Ga Ex d ia I Mb Ex d ia IIC T4/T3 Gb |
CE mark |
Electromagnetic Compatibility (Directive 2004/108/EC); ATEX (Directive 94/9/EC) |
MED |
Marine Equipment Directive (Directive 96/98/EC) |
1) According to the regulations of T021/T023
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde
There are no reviews yet.