Dräger X-am 2500 FLEX
The Dräger X-am 2500 FLEX is a versatile and robust gas detector specially designed for use in demanding environments. It is ideal for monitoring gases in the chemical, construction and biotechnology industries. Thanks to its innovative technology and flexible application options, it offers precise measurements and high reliability. Compared to similar products such as the Dräger X-plore 3500, the X-am 2500 FLEX is characterized by its stepless adjustment and waterproof design.
Technical data and functions
The Dräger X-am 2500 FLEX is equipped with various sensors that can monitor a wide range of gases. Here are the most important technical data:
-
EX sensor:
- Measuring range: 0 - 100 % LEL, 0 - 5 vol.% CH₄
- Resolution: 1 % LEL
- Response time (t₉₀): 10 seconds
- Service life: > 4 years
-
O₂ sensor:
- Measuring range: 0 - 25 % by volume
- Resolution: 0.1 % by volume
- Response time (t₉₀): 10 seconds
- Service life: > 5 years
-
CO sensor:
- Measuring range: 0 - 2,000 ppm
- Resolution: 2 ppm
- Response time (t₉₀): 15 seconds
- Service life: > 5 years
-
H₂S-LC sensor:
- Measuring range: 0 - 100 ppm
- Resolution: 0.1 ppm
- Response time (t₉₀): 15 seconds
- Service life: > 5 years
-
SO₂ sensor:
- Measuring range: 0 - 100 ppm
- Resolution: 0.1 ppm
- Response time (t₉₀): 15 seconds
- Service life: > 3 years
-
NO₂ sensor:
- Measuring range: 0 - 50 ppm
- Resolution: 0.1 ppm
- Response time (t₉₀): 15 seconds
- Service life: > 3 years
Further technical specifications include:
- Dimensions: 48 x 130 x 44 mm
- Weight: 220 - 250 g
- Operating temperature: -20 to +50 °C
- Protection class: IP 67
- Operating times: > 12 h with alkaline and NiMH, > 13 h with NiMH HC, without Ex sensor typ. > 250 h with alkaline batteries
- Charging times: < 4 h
- Data memory: Readable via infrared interface, > 1000 h with 4 gases at a recording interval of 1 value per minute
Certifications and standards
The Dräger X-am 2500 FLEX complies with numerous international standards and certifications, including
-
ATEX: I M1 Ex ia I Ma, II 1G Ex ia IIC T3 Ga, I M2 Ex d ia I Mb, II 2G Ex d ia IIC T4/T3 Gb
-
EN 50104(2002)+A1(2004): O₂
- EN45544: CO & H₂S
-
EN 60079-29-1:2007: Methane to nonane
-
EN 50271:2001: Software and documentation
-
CSA (Canada & USA): Class I Div. 1 Group A, B, C, D T.-Code T4/T3, A/Ex ia IIC T3 /Ga, A/Ex d ia IIC T4/T3 /Gb
-
IECEx: Ex ia I Ma, Ex ia IIC T3 Ga, Ex d ia I Mb, Ex d ia IIC T4/T3 Gb
-
CE mark: Electromagnetic compatibility (Directive 2004/108/EC); ATEX (Directive 94/9/EC)
-
MED: Marine Equipment Directive (Directive 96/98/EC)
Application examples
The Dräger X-am 2500 FLEX is ideal for monitoring gases in various industries and applications:
-
Chemical industry: Monitoring of methane and other hydrocarbons
-
Construction industry: monitoring of oxygen and carbon monoxide in enclosed spaces
-
Biotechnology: Monitoring of hydrogen sulphide and nitrogen dioxide in biochemical processes
-
Laboratory applications: Monitoring of oxygen and other gases in DNA analyses and enzymatic reactions
FAQs
How long does the battery of the Dräger X-am 2500 FLEX last?
- The battery lasts > 12 hours with alkaline and NiMH, > 13 hours with NiMH HC and without Ex sensor typ. > 250 hours with alkaline batteries.
Which gases can the Dräger X-am 2500 FLEX monitor?
- The X-am 2500 FLEX can monitor gases such as methane (CH₄), oxygen (O₂), carbon monoxide (CO), hydrogen sulphide (H₂S), sulphur dioxide (SO₂) and nitrogen dioxide (NO₂).
Is the Dräger X-am 2500 FLEX waterproof?
- Yes, the X-am 2500 FLEX has protection class IP 67 and is therefore waterproof.
How often does the Dräger X-am 2500 FLEX need to be calibrated?
- The calibration interval is preset to 122 days (4 months).
Conclusion
The Dräger X-am 2500 FLEX is a reliable and versatile gas detector that is characterized by its robust design and precise measurements. It is ideal for use in various industries and applications and offers a high degree of flexibility and user-friendliness. Similar products such as the Dräger X-plore 4790 also offer high quality and reliability, but with different specifications and applications.
Shipping weight: |
0,94 kg
|
Item weight: |
0,94 kg
|
|
Dräger X-am® 2500 |
|
|
sensors |
EX |
Measuring range |
0 - 100 % LEL 0 - 5 Vol.-% CH4
|
Resolution |
1 % LEL |
Response time (t90) |
10 Sec. |
Expected service life |
> 4 years |
|
|
sensors |
O2 |
Measuring range |
0 - 25 Vol.-% |
Resolution |
0,1 Vol.-% |
Response time (t90) |
10 Sec. |
Expected service life |
> 5 years |
|
|
sensors |
CO |
Measuring range |
0 - 2.000 ppm |
Resolution |
2 ppm |
Response time (t90) |
15 Sec. |
Expected service life |
> 5 years |
|
|
sensors |
H2S-LC |
Measuring range |
0 - 100 ppm |
Resolution |
0,1 ppm |
Response time (t90) |
15 Sec. |
Expected service life |
> 5 years |
|
|
sensors |
SO2 |
Measuring range |
0 - 100 ppm |
Resolution |
0,1 ppm |
Response time (t90) |
15 Sec. |
Expected service life |
> 3 years |
|
|
sensors |
NO2 |
Measuring range |
0 - 50 ppm |
Resolution |
0,1 ppm |
Response time (t90) |
15 Sec. |
Expected service life |
> 3 years |
|
|
Dimensions (W x H x D) |
48 x 130 x 44 mm |
Weight |
220 - 250 g |
Ambient conditions |
|
Temperature |
- 20 bis + 50 °C |
Pressure |
700 bis 1300 mbar |
Relative humidity |
10 bis 95 % r. H. |
Protection class |
IP 67 |
Alarms |
|
Visual |
360 ° |
Audible |
Multi-tone > 90 dB at 30 cm |
Vibration |
|
Operating times |
> 12 h with alkaline and NiMH > 13 h with NiMH HC, > 250 h w/o Ex sensor with alkaline batteries |
Charging time |
< 4 h |
Datalogger |
Retrievable using an infrared interface > 1000 h with 4 gases at a recording interval of 1 value per minute |
Default setting Calibration interval1
|
122 days (4 month) |
Approvals |
|
ATEX |
I M1 Ex ia I Ma, II 1G Ex ia IIC T3 Ga, I M2 Ex d ia I Mb, II 2G Ex d ia IIC T4/T3 Gb |
Performance approval to: |
EN 50104(2002)+A1(2004): O2 EN 45544: CO & H2S EN 60079-29-1:2007: Methane to nonane EN 50271:2001: Software and documentation |
CSA (Kanada & USA) |
Class I Div. 1 Group A, B, C, D T.-Code T4/T3 A/Ex ia IIC T3 /Ga A/Ex d ia IIC T4/T3 /Gb |
IECEx |
Ex ia I Ma Ex ia IIC T3 Ga Ex d ia I Mb Ex d ia IIC T4/T3 Gb |
CE mark |
Electromagnetic Compatibility (Directive 2004/108/EC); ATEX (Directive 94/9/EC) |
MED |
Marine Equipment Directive (Directive 96/98/EC) |
1) According to the regulations of T021/T023