Dräger PAC 5500
The Dräger PAC 5500 is a high-precision gas detector specially developed for use in demanding environments. It offers reliable measurement accuracy and is ideal for monitoring carbon monoxide (CO), hydrogen sulphide (H₂S) and oxygen (O₂). Thanks to its robust design and user-friendly interface, it is an indispensable tool for professionals in industry, construction and environmental monitoring. Similar to the Dräger PAC 6500, the PAC 5500 offers high reliability and precision.
Technical data and functions
The Dräger PAC 5500 is characterized by the following technical data and functions:
-
Measuring ranges:
- CO: 0 - 500 ppm
- H₂S: 0 - 100 ppm
- O₂: 0 - 25 vol.-%
-
Alarm thresholds:
- CO: 30 / 60 ppm (standard) or according to customer requirements
- H₂S: 5 / 10 ppm (standard) or according to customer requirements
- O₂: 19 / 23 vol.% (standard) or according to customer requirements
-
Resolution:
- CO: 2 ppm
- H₂S: 0.1 ppm
- O₂: 0.1 % by volume
-
Response time T90:
- CO and H₂S: 15 seconds
- O₂₂: 10 seconds
These technical data make the PAC 5500 a versatile and precise measuring device that can be used in various applications.
Areas of application
The Dräger PAC 5500 is ideal for monitoring gases in various industries and applications:
-
Industry: monitoring CO and H₂S in production facilities and warehouses.
-
Construction: Monitoring air quality on construction sites, especially in enclosed spaces.
-
Environmental monitoring: measurement of O₂ concentrations in ambient air.
-
Chemical industry: monitoring hazardous gases in production processes.
Thanks to its robust and waterproof design, the PAC 5500 is also suitable for use in harsh environments. Similar to the Dräger X-plore 3500, the PAC 5500 offers high durability and reliability.
Certifications and standards
The Dräger PAC 5500 complies with all relevant certifications and standards to ensure safe and reliable measurement. These include:
-
CE marking: conformity with European safety and health requirements.
-
DIN standards: Compliance with German industry standards for measuring devices.
FAQs
How long does the battery of the Dräger PAC 5500 last?
The battery of the Dräger PAC 5500 has a service life of up to two years, depending on usage and environmental conditions.
Can the PAC 5500 be used in potentially explosive atmospheres?
Yes, the Dräger PAC 5500 is certified for use in potentially explosive atmospheres and meets the relevant safety requirements.
How often should the PAC 5500 be calibrated?
It is recommended that the PAC 5500 is calibrated regularly to ensure measurement accuracy. The calibration intervals depend on the operating conditions and the specific requirements.
Conclusion
The Dräger PAC 5500 is a reliable and accurate gas detector that is ideal for use in a variety of industries. With its versatile functions and robust features, it offers high measurement accuracy and reliability. For professionals who need a reliable gas detector, the PAC 5500 is an excellent choice. Similar to the Dräger X-plore 5500, the PAC 5500 offers high performance and reliability in demanding environments.
Variations |
Measuring range |
Alarm threshold A1/A2 (standard) |
Resolution |
Response time T90
|
CO 1)
|
0 - 500 ppm |
30 /60 ppm |
2 ppm |
15 sec. |
CO |
0 - 500 ppm |
customer request |
2 ppm |
15 sec. |
H2S 1)
|
0 - 100 ppm |
5 /10 ppm |
0,1 ppm |
15 sec. |
H2S |
0 - 100 ppm |
customer request |
0,1 ppm |
15 sec. |
O2 1)
|
0 - 25 Vol.-% |
19 /23 Vol.-% |
0,1 Vol.-% |
10 sec. |
O2
|
0 - 25 Vol.-% |
customer request |
0,1 Vol.-% |
10 sec. |
1) Standard configuration europe