BINDER ULTRA.GUARD UF V 700 ultra-low temperature freezer
The BINDER ULTRA.GUARD UF V 700 ultra-low temperature freezer is the ideal solution for the safe storage of samples, vaccines and medicines in laboratories. With its high-quality workmanship and excellent performance, it sets new standards in laboratory freezing technology. This ultra-low temperature freezer offers reliable temperature control and a variety of safety features that make it a preferred choice over similar products on the market. Similar to the BINDER UF V 500 ULT freezer, the UF V 700 offers outstanding performance and reliability.
Technical data and functions
The BINDER ULTRA.GUARD UF V 700 ULT freezer is equipped with the latest technology to ensure optimal storage of temperature-sensitive materials. Here are some of the most important technical data and functions:
-
Temperature range: Adjustable from -90 °C to -40 °C, control range from -86 °C to -40 °C
-
Cooling technology: Static cooling
-
Dimensions: External dimensions (W x H x D) 1200 mm x 1970 mm x 940 mm, internal dimensions (W x H x D) 911 mm x 1300 mm x 600 mm
-
Cooling capacity: 711 liters
-
Energy consumption: 16.2 kWh/24h
-
Alarm functions: Visual and acoustic alarm for temperature deviations and door opening
-
Material: Outer housing made of stainless steel with impact and shock-resistant powder coating, door with environmentally friendly insulation
Temperature regulation and safety
The temperature of the UF V 700 is regulated electronically and can also be secured by a key system. This ensures uniform temperature distribution and protects sensitive materials such as pharmaceutical products and biologicals from temperature fluctuations. In contrast to the Liebherr SUFsg MediLine ultra-low temperature freezer, the UF V 700 offers more precise temperature control and additional safety functions.
Convenience and energy efficiency
The BINDER ULTRA.GUARD UF V 700 is equipped with automatic defrosting, which significantly reduces maintenance work. The appliance door closes automatically and is lockable, which provides additional security. The insulation of the door is made of robust, insulating material, which minimizes energy consumption and protects the environment. Similar to the FRYKA TUS freezer base cabinet, the UF V 700 is designed to reduce energy consumption while offering maximum performance.
Application examples
The BINDER ULTRA.GUARD UF V 700 ultra-low temperature freezer is ideal for the storage of:
-
Laboratory samples: Ensuring the integrity of biological samples at extremely low temperatures
-
Vaccines: Long-term storage of vaccines that are sensitive to temperature fluctuations
-
Medication: Storage of temperature-sensitive medicines to maintain their efficacy
Certifications and standards
The UF V 700 meets the requirements of DIN 12880 and is certified in accordance with the BINDER factory standard. This guarantees the highest quality and reliability in the storage of temperature-sensitive materials.
FAQs
How is the temperature controlled in the BINDER ULTRA.GUARD UF V 700?
Temperature control is electronic and can be secured by a key system. This enables precise control and even distribution of the temperature throughout the entire interior.
What safety functions does the UF V 700 offer?
The ultra-low temperature freezer is equipped with visual and audible alarms that are activated in the event of temperature deviations or door openings. An integrated door opening alarm sounds after approx. 60 seconds if the door is opened unintentionally.
How high is the energy consumption of the UF V 700?
The average energy consumption is 16.2 kWh/24h, which is achieved by the efficient insulation and the self-closing door.
Conclusion
The BINDER ULTRA.GUARD UF V 700 ultra-low temperature freezer is a first-class choice for laboratories that require reliable and safe storage of temperature-sensitive materials. With its advanced temperature control, extensive safety functions and high energy efficiency, it sets new standards in laboratory freezing technology. Comparisons such as with the BINDER UF V 500 ultra-low temperature freezer and Liebherr SUFsg MediLine ultra-low temperature freezer show that the UF V 700 is an outstanding choice for demanding applications.
alarm: |
acoustical, optical |
Scope of application: |
laboratory freezer |
Width (refrigerator): |
1200 mm |
Width inside (refrigerator): |
911 mm |
Glass door: |
without |
Height (refrigerator): |
1970 mm |
Height inside (refrigerator): |
1300 mm |
Cooling capacity (gross): |
711 l |
Cooling technology: |
upright freezer |
Cooling (Cooling technology): |
static |
Average consumption: |
16.200 kWh/24h |
Depth (refrigerator): |
940 mm |
Depth inside (refrigerator): |
600 mm |
Lowest temperature: |
- 86°C |
lockable: |
no |
automatic defrost: |
without |
Explosion proof: |
no |
BINDER ultra low temperature freezer |
ULTRA.GUARDTM UF V 700
|
Exterior dimensions |
|
Width including hinges, housing of door lock and controller (mm) |
1200 |
Height including vertically adjustable castors (mm) |
1970 |
Depth (mm) |
890 |
Depth including power connection, housing of door lock and controller (mm) |
940 |
Wall clearance rear (mm) |
100 |
Wall clearance side (side without hinges) (mm) |
100 |
Wall clearance side (side with hinges) (mm) |
245 |
Interior dimensions |
|
Number of compartments |
4 |
Number of shelves |
3 |
Width of interior (mm) |
911 |
Width of shelf (mm) |
880 |
Height of interior (mm) |
1300 |
Depth of interior / Depth of shelf (mm) |
600 |
Interior volume, total (l) |
711 |
Permitted load of individual compartment (kg) |
65 |
Permitted total load (kg) |
260 |
Weight of the unit (empty) (kg) |
360 |
Temperature data |
|
Control range (°C) |
-86 bis -40 |
Setting range (°C) |
-90 bis -40 |
Average temperature variation (±K) 3) |
2,5 |
Cooling down time from +25 °C to -80 °C (h) 1) |
9 |
Heating up time in case of power failure from -80 °C to -60 °C (h) |
3 |
Electrical data |
|
IP protection class according to EN 60529 |
20 |
Nominal voltage (±10 %) 50 Hz (V) |
230 |
Energy consumption at -80 °C and Tu = 25 °C (KWh/day) |
16,2 |
Average heat dissipation at set value -80 °C and Tu = 25 °C (W) 2) |
680 |
Noise level (dB(A)) |
49 |
1) to 98% of the set value with empty freezer
2) These values can be used for evaluation of air-conditioning systems.
3) at -80 °C
All technical data are specified for unloaded units with standard equipment at an ambient temperature of +25 °C and a voltage fluctuation of ±10%. The temperature data are determinated in accordance to BINDER factory standard following DIN 12880 respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.