BINDER UF V 700 ultra deep freezer
The BINDER UF V 700 ultra-low temperature freezer is a state-of-the-art freezer that has been specially developed for use in laboratories. With an impressive ultra-low temperature of -90°C and a generous interior volume of 700 liters, this appliance offers optimum conditions for storing temperature-sensitive materials. Thanks to its energy-efficient technology and the use of environmentally friendly refrigerants such as R-290 and R-170, the UF V 700 sets new standards in terms of sustainability and energy consumption. Similar to the BINDER UF V 500 ultra-low temperature freezer, the UF V 700 offers reliable and safe storage for your valuable samples.
Technical data and functions
The BINDER UF V 700 ultra-low temperature freezer is characterized by a variety of technical features that make it an ideal choice for laboratories:
-
Temperature range: -90°C to -40°C
-
Interior volume: 700 liters
-
Dimensions (W x H x D): 1110 mm x 1966 mm x 938 mm
-
Internal dimensions (W x H x D): 890 mm x 1300 mm x 605 mm
-
Refrigerant: R-290 and R-170
-
Energy consumption: 8,100 kWh/24h
-
Power consumption: 10 A
-
Noise level: 47 dB(A)
-
Maximum load per compartment: 50 kg
-
Maximum total load: 200 kg
-
Alarm functions: Audible and visual
The temperature is controlled electronically and can also be secured by a key system. This ensures uniform temperature distribution and reliable storage of pharmaceuticals, medicines or temperature-sensitive biologicals. In contrast to the Liebherr SUFsg MediLine ultra-low temperature freezer, the UF V 700 offers a particularly low spatial temperature deviation of just 2.5 K at -80°C.
Certifications and standards
The BINDER UF V 700 ultra-low temperature freezer meets the strict requirements of DIN 12880:2007 and is certified in accordance with the BINDER factory standard. This guarantees the highest quality and reliability when storing your samples.
Application examples
The UF V 700 is ideal for a wide range of applications in laboratories:
-
Pharmaceutical research: storage of vaccines, medicines and other temperature-sensitive substances.
-
Biotechnology: Storage of cell cultures, enzymes and other biological samples.
-
Chemical industry: Storage of reactive chemicals and solvents.
-
Clinical laboratories: Storage of blood samples, tissue samples and other medical materials.
FAQs
How long does the freezer stay cold in the event of a power failure?
The UF V 700 can maintain a temperature of -80°C to -60°C for around 250 minutes in the event of a power failure. This provides sufficient time to take measures to restore the power supply.
What safety functions does the UF V 700 offer?
The freezer is equipped with audible and visual alarms that warn immediately in the event of temperature deviations or other faults. An integrated door opening alarm sounds after approx. 60 seconds if the door is opened unintentionally. A monitoring unit can remain in operation for around 30 hours via the rechargeable battery, so that you remain informed even in the event of a power failure.
Is the UF V 700 environmentally friendly?
Yes, the UF V 700 uses the climate-neutral refrigerants R-290 and R-170, which reduce energy consumption and are environmentally friendly. The insulation of the door is made of robust, insulating and environmentally friendly material, which also contributes to energy efficiency.
Conclusion
The BINDER UF V 700 ultra-low temperature freezer is a powerful and reliable appliance that has been specially developed for the demanding requirements of laboratories. With its high energy efficiency, extensive safety functions and large storage capacity, it is the ideal choice for storing temperature-sensitive materials. Similar to the FRYKA TUS freezer base cabinet, the UF V 700 offers outstanding performance and reliability that can optimize your laboratory processes.
alarm: |
acoustical, optical |
Scope of application: |
laboratory freezer |
Width (refrigerator): |
1110 mm |
Width inside (refrigerator): |
890 mm |
Noise level: |
47 dB(A) |
Glass door: |
without |
Height (refrigerator): |
1966 mm |
Height inside (refrigerator): |
1300 mm |
Refrigerant: |
R-170, R-290 |
Cooling capacity (gross): |
700 l |
Cooling technology: |
upright freezer |
Cooling (Cooling technology): |
static |
Average consumption: |
8.100 kWh/24h |
Power consumption: |
10 A |
Depth (refrigerator): |
938 mm |
Depth inside (refrigerator): |
605 mm |
Lowest temperature: |
- 90°C |
lockable: |
no |
automatic defrost: |
without |
Explosion proof: |
no |
Item weight: |
288,00 kg
|
BINDER Ultra low temperature freezer |
UFV700-230V1
|
UFV700-230V-W1 |
UFV700UL-120V1 |
UFV700UL-240V1
|
Option model |
Standard |
Water cooling |
Standard |
Standard |
Performance Data Temperature |
|
|
|
|
Cooling down time from 22 °C to -80 °C [min] |
450 |
450 |
450 |
450 |
Warm-up time during power failure from -80 °C to -60 °C [min] |
250 |
250 |
250 |
250 |
Temperature variation at -80 °C [+ K] |
2.5 |
2.5 |
2.5 |
2.5 |
Temperature range [°C] |
-90 to -40 |
-90 to -40 |
-90 to -40 |
-90 to -40 |
Temperature fluctuation at -80 °C [+ K] |
1.5 |
1.5 |
1.5 |
1.5 |
Electrical data |
|
|
|
|
Unit fuse [A] |
10 |
10 |
13 |
10 |
Nominal power [kW] |
1.6 |
1.6 |
1.4 |
1.6 |
Rated Voltage [V] |
230 |
230 |
120 |
240 |
Power frequency [Hz] |
50 |
50 |
60 |
60 |
Phase (Nominal voltage) |
1~ |
1~ |
1~ |
1~ |
Doors |
|
|
|
|
Unit doors |
1 |
1 |
1 |
1 |
Outer dimensions |
|
|
|
|
Width net [mm] |
1110 |
1110 |
1110 |
1110 |
Height net [mm] |
1966 |
1966 |
1966 |
1966 |
Depth net [mm] |
938 |
938 |
938 |
938 |
Internal Dimensions |
|
|
|
|
Width [mm] |
890 |
890 |
890 |
890 |
Height [mm] |
1300 |
1300 |
1300 |
1300 |
Depth [mm] |
605 |
605 |
605 |
605 |
Measures |
|
|
|
|
Net weight of the unit (empty) [kg] |
288 |
288 |
288 |
288 |
Interior volume [L] |
700 |
700 |
700 |
700 |
Permitted load of individual compartment [kg] |
50 |
50 |
50 |
50 |
Permitted load [kg] |
200 |
200 |
200 |
200 |
Wall clearance back [mm] |
100 |
100 |
100 |
100 |
Wall clearance sidewise [mm] |
250 |
250 |
250 |
250 |
Environment-specific data |
|
|
|
|
Average heat dissipation at set-point -80 °C and ambient temperature = 21 °C [W] |
340 |
340 |
340 |
340 |
Energy consumption at set-point -80 °C and ambient temperature = 21 °C [kWh/d] |
8.1 |
8.1 |
8.1 |
8.1 |
Sound-pressure level [dB(A)] |
47 |
47 |
47 |
47 |
Fixtures |
|
|
|
|
Number of shelves (std./max.) |
3/13 |
3/13 |
3/13 |
3/13 |
Load-variants |
|
|
|
|
Freezer racks per compartment |
6 |
6 |
6 |
6 |
Cryoboxes, 50 mm |
528 |
528 |
528 |
528 |
1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C
+3 °C and a power supply voltage fluctuation of
+10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde
There are no reviews yet.