BINDER FP 240 materials testing chamber
The BINDER FP 240 material test chamber is a highly sophisticated unit specially designed for use in laboratories and medical facilities. This chamber is ideal for the cultivation of microorganisms, insect or animal cultures as well as for various breeding and development processes. Thanks to its precise temperature and humidity control, the FP 240 is also ideal for studying and analyzing cell behaviour and growth. Compared to similar products such as the BINDER FP 400 material test chamber, the FP 240 offers a more compact solution with the same performance.
Technical data and equipment
The BINDER FP 240 materials test chamber is characterized by a number of technical features that make it an indispensable tool in any laboratory:
-
Chamber type: Material test chamber
-
Maximum load: 51 - 100 kg
-
Internal volume: 201 - 300 l
-
Maximum temperature: +300 °C
-
External dimensions: Width 1235 mm, height 1025 mm, depth 765 mm
-
Internal dimensions: Width 1000 mm, height 800 mm, depth 510 mm
-
Temperature range: approx. 5 °C above room temperature up to 300 °C
-
Temperature deviation: ±0.8 K at 70 °C, ±2 K at 150 °C, ±4.3 K at 300 °C
-
Heating time: 12 minutes at 70 °C, 27 minutes at 150 °C, 50 minutes at 250 °C
-
Recovery time after 30 seconds of door opening: 2 minutes at 70 °C, 10 minutes at 150 °C, 16 minutes at 300 °C
-
Air exchange rate: 19x/h at 70 °C, 20x/h at 150 °C, 18x/h at 300 °C
-
Energy consumption: 370 W at 70 °C, 850 W at 150 °C, 1400 W at 300 °C
-
IP protection class: IP 20 according to EN 60529
-
Rated voltage: 230 V, 50/60 Hz
-
Rated power: 2.7 kW
Special features
The FP 240 is equipped with a wide range of functions that make it particularly user-friendly and efficient:
- Controller for simultaneous display of all relevant information
- Easy to operate
- Electronic line recorder
- Graphic display options for the process parameters
- VENTAIR™ air jacket system (depending on model)
- Real-time clock
- Standard-compliant hot air sterilization at 180 °C (DIN 58947)
- Drift-free CO2 infrared absorption measuring system
- ANTI.PLENUM design to avoid contamination-critical installations
- Permadry™ system, double tray humidification system with defined condensation location
- Electronic fault auto-diagnostic system with visual and audible alarm
- Potential-free changeover contact for central monitoring
- Temperature selector monitor with visual and audible temperature alarm
- Tight-closing inner door
- Ethernet interface for APT-COM™ DataControlSystem communication software
- Optional: Multiple stainless steel shelves
- BINDER test certificate
Certifications and standards
The BINDER FP 240 meets the strict requirements of DIN 58947 for hot air sterilization at 180 °C. This ensures a high level of reliability and safety during operation.
Application examples
The FP 240 material test chamber can be used for a wide range of applications and is particularly suitable for
-
Cultivation of microorganisms: Ideal for research and development in microbiology.
-
Incubation and development processes: Perfect for breeding insect and animal cultures.
-
Cell growth analyses: Indispensable for investigating cell behavior and growth.
-
Material testing: Suitable for testing materials under different temperature and humidity conditions.
FAQs
What is the maximum load of the FP 240?
The maximum load of the FP 240 is 100 kg.
What temperature ranges does the FP 240 cover?
The FP 240 covers temperature ranges from approx. 5 °C above room temperature to 300 °C.
Is the FP 240 suitable for hot air sterilization?
Yes, the FP 240 is suitable for standard-compliant hot air sterilization at 180 °C in accordance with DIN 58947.
What safety functions does the FP 240 offer?
The FP 240 has an electronic fault auto-diagnosis system with visual and audible alarm and a temperature selection monitor with visual and audible temperature alarm.
Conclusion
The BINDER FP 240 materials testing chamber is a versatile and reliable device that is indispensable in laboratories and medical facilities. With its extensive functions and high safety standards, it offers an optimum solution for a wide range of applications. Similarly equipped products such as the BINDER FP 400 materials testing chamber offer additional options for specific requirements.
| Item information |
Value |
| Load max.: |
51 - 100 kg |
| Width outside (incubators,...): |
1235 mm |
| Width inside (incubators,...): |
1000 mm |
| Maximum temperature (heat): |
+ 300 °C |
| Height outside (incubators,...): |
1025 mm |
| Height inside (incubators,...): |
800 mm |
| Interior volume: |
201 - 300 l |
| Cabinet type: |
material test chamber |
| Depth outside (incubators,...): |
765 mm |
| Depth inside (incubators,...): |
510 mm |
| BINDER Material test chamber |
FP 240 |
| Exterior dimensions |
|
| Width (mm) |
1035 |
| Height (inkl. Füße) (mm) |
825 |
| Depth (mm) |
745 |
| Plus door handle and connection (mm) |
105 |
| Wall clearance, rear (mm) |
100 |
| Wall clearance, side (mm) |
160 |
| Exhaust duct (Außen-Ø mm) |
52 |
| Steam space volume (l) |
308 |
| Number of doors (ea.) |
2 |
| Interior dimensions |
|
| Width (mm) |
800 |
| Height (mm) |
600 |
| Depth (mm) |
510 |
| Interior volume (l) |
240 |
| Racks (number standard/max.) |
2 / 7 |
| Load per rack (kg) |
30 |
| Permitted total load (kg) |
70 |
| Weight (empty) (kg) |
98 |
| Temperature data |
|
| Temperature range approx. 5 °C above ambient temperature to(°C) |
300 |
Temperature variation at 70 °C (± K) at 150 °C (± K) at 300 °C (± K) |
0,8 2 4,3 |
| Temperature fluctuation (± K) |
0,3 |
Warm-up time to 70 °C (min.) to 150 °C (min.) to 250 °C (min.) |
12 27 50 |
Recovery time after doors were open for 30 sec. 1) at 70 °C (min.) at 150 °C (min.) at 300 °C (min.) |
2 10 16 |
| Ventilation data |
|
Ventilation at 70 °C (x/h) at 150 °C (x/h) at 300 °C (x/h) |
19 20 18 |
| Electrical data |
|
| IP protection class acc. to EN 60529 |
IP 20 |
| Voltage (± 10%) 50 / 60 Hz (V) |
230, 1 N ~ |
| Nominal power (kW) |
2,7 |
Energy consumption at 70 °C (W) at 150 °C (W) at 300 °C (W) |
370 850 1400 |
1) To 98% of the set value
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.