BINDER KB 720 cooling incubator
The BINDER KB 720 cooling incubator is a versatile all-rounder for laboratories and other work areas. It is ideal for cultivating microorganisms, insect or animal cultures as well as for various breeding and development processes. The incubator makes it possible to observe the behavior and growth of cells and draw specific conclusions from this. Thanks to its precise control of temperature, humidity and other conditions such as carbon dioxide and oxygen levels, the KB 720 creates optimum conditions for a wide range of applications in biology, chemistry, medicine and the food industry.
Similar to the BINDER KBW 720 growth chamber, the KB 720 provides a reliable and controlled environment for your research and development work.
Technical data and features
The BINDER KB 720 cooling incubator is characterized by a wide range of technical data and features that make it an indispensable unit in many laboratories:
-
Incubator type: Cooling incubator
-
Max. load: 101 - 150 kg
-
Internal volume: 601 - 700 l
-
Maximum temperature (heat): +100 °C
-
Lowest temperature (cooling): -5 °C
-
External height: 1925 mm
-
Width inside: 970 mm
-
Interior height: 1250 mm
-
Depth inside: 576 mm
-
Width outside: 1250 mm
-
External depth: 885 mm
Performance data Temperature
-
Temperature range: -5 to 100 °C
-
Spatial temperature deviation at 37 °C: ±0.2 K
-
Temporal temperature dev iation at 37 °C: ±0.1 K
-
Recovery time after 30 s door opening at 37 °C: 3 minutes
Electrical data
-
Rated voltage: 200 - 240 V
-
Mains frequency: 50/60 Hz
-
Rated power: 2.3 kW
-
Appliance fuse: 16 A
-
Phase (rated voltage): 1~
Housing dimensions
-
Net width: 1250 mm
- Netheight: 1925 mm
- Netdepth: 885 mm
-
Rear wall clearance: 100 mm
-
Lateral wall clearance: 100 mm
Interior dimensions
-
Width: 970 mm
-
Height: 1250 mm
-
Depth: 576 mm
-
Interior volume: 698 l
-
Net appliance weight (empty): 304 kg
-
Maximum total load: 150 kg
-
Maximum load per drawer: 45 kg
Environmentally relevant data
-
Energy consumption at 37 °C: 360 Wh/h
-
Sound pressure level: 53 dB(A)
Built-in units
-
Number of shelves (standard/maximum): 2/15
Certifications and standards
The BINDER KB 720 cooling incubator meets the requirements of the BINDER factory standard and is based on DIN 12880:2007. These standards guarantee the high quality and reliability of the unit.
Application examples
The KB 720 is used in various areas:
-
Biology: Cultivation of microorganisms and cell cultures
-
Chemistry: Storage and incubation of chemical samples
-
Medicine: research on cell and tissue cultures
-
Food industry: Investigation of the growth of microorganisms in foodstuffs
FAQs
How is the temperature controlled in the BINDER KB 720 cooling incubator?
The temperature is displayed and set digitally via an LED display. This enables precise control and monitoring of the temperature conditions in the incubator.
What safety functions does the KB 720 offer?
The KB 720 has a practical door lock and an ergonomic control and information panel to ensure safe handling.
How many trays can be used in the KB 720?
The KB 720 offers space for up to 15 drawers, with 2 drawers included as standard.
Conclusion
The BINDER KB 720 cooling incubator is a powerful and versatile unit that is indispensable in many laboratories. With its precise temperature control, large internal volume and numerous safety functions, it offers optimum conditions for a wide range of applications in research and industry. Similar to the BINDER KMF720 constant climate chamber, the KB 720 is an excellent choice for demanding laboratory work.
Load max.: |
101 - 150 kg |
Width outside (incubators,...): |
1250 mm |
Width inside (incubators,...): |
970 mm |
Maximum temperature (heat): |
+ 100 °C |
Height outside (incubators,...): |
1925 mm |
Height inside (incubators,...): |
1250 mm |
Incubator model: |
cooling incubator |
Interior volume: |
601 - 700 l |
Depth outside (incubators,...): |
885 mm |
Depth inside (incubators,...): |
576 mm |
Lowest temperature (cooling): |
- 5 °C |
BINDER Cooling incubator |
KB 720-230V |
KB 720UL-240V |
Performance Data Temperature |
|
|
Temperature range [°C] |
-5..100 |
-5..100 |
Temperature variation at 37 °C [± K] |
0.2 |
0.2 |
Temperature fluctuation at 37 °C [± K] |
0.1 |
0.1 |
Recovery time after 30 seconds door open at 37 °C [min] |
3 |
3 |
Electrical data |
|
|
Rated Voltage [V] |
200...240 |
200...240 |
Power frequency [Hz] |
50/60 |
50/60 |
Nominal power [kW] |
2.3 |
2.3 |
Unit fuse [A] |
16 |
16 |
Phase (Nominal voltage) [ph] |
1 |
1 |
Outer dimensions not incl. fittings and connections |
|
|
Width net [mm] |
1250 |
1250 |
Height net [mm] |
1925 |
1925 |
Depth net [mm] |
885 |
885 |
Wall clearance back [mm] |
100 |
100 |
Wall clearance sidewise [mm] |
100 |
100 |
Doors |
|
|
Inner doors |
2 |
2 |
Unit doors |
2 |
2 |
Internal Dimensions |
|
|
Width [mm] |
970 |
970 |
Height [mm] |
1250 |
1250 |
Depth [mm] |
576 |
576 |
Measures |
|
|
Interior volume [L] |
698 |
698 |
Net weight of the unit (empty) [kg] |
304 |
304 |
|
permitted load [kg] |
150 |
150 |
Load per rack [kg] |
45 |
45 |
Environment-specific data |
|
|
Energy consumption at 37 °C [Wh/h] |
360 |
360 |
Sound-pressure level [dB(A)] |
53 |
53 |
Fixtures |
|
|
Number of shelves (std./max.) |
2/15 |
2/15 |
All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde
There are no reviews yet.