The KB 23 from Binder is a true all-rounder for the laboratory and many other work areas. Use the model for a wide variety of laboratory tasks. In the laboratory or in medicine, for example, this includes the cultivation of microorganisms, bacterial or animal cultures and numerous breeding or development processes. With the KB 23 you can also observe the behaviour of cells and their growth. Conclusions can often be drawn more easily this way.
The KB 23: Optimal incubator for laboratory and medicine
Activities such as the creation, investigation or maintenance of (cell) growth processes can be optimally implemented with the KB 23.
The good humidity and temperature conditions are due to the perfectly designed interior. . Depending on the type or model, the Binder incubator has a timer, a temperature controller and usually also a device for regulating the fresh air supply. In addition, depending on the model, you will find the following equipment in Binder incubators:
- An easy-to-operate controller for the clear display of all relevant information.
- A user-friendly control system
- An electronic chart recorder
- Various graphical display options for the process parameters
- Depending on the model, a VENTAIRTM air jacket system
- A real-time clock
- Depending on the model, a standard-compliant sterilisation system for medical air at 180 C (DIN 58947)
- A drift-free CO2 infrared absorption measuring system
- ANTI.PLENUM design to prevent contamination-critical fixtures-
- A PermadryTM system, double tray humidification system with defined condensation point
- An electronic fault auto-diagnostic system with visual and audible alarm
- A potential-free change-over contact for central monitoring
- Temperature monitor with visual and audible temperature alarm
- One sealed internal door
- One Ethernet interface for communication software APT-COMTM DataControlSystem
- Optional: Multiple stainless steel racks
- The BINDER test certificate
Incubator type: Cooling incubatorMax. load: 11 - 50 kgInternal volume: up to 50 l
You can find out even more about our instruments, the various instruments or our brand manufacturer from our team of experts.
We answer your questions
Our team of experienced consultants wants you to get the best instruments for your laboratory. Do you have questions about our various products, their advantages or the respective brand manufacturers?
We will be happy to assist you and can be contacted daily by telephone on +49 30 2096579 00 or by e-mail at info@medsolut.com. We look forward to hearing from you!
Load max.: |
11 - 50 kg |
Width outside (incubators,...): |
435 mm |
Width inside (incubators,...): |
222 mm |
Maximum temperature (heat): |
+ 100 °C |
Height outside (incubators,...): |
620 mm |
Height inside (incubators,...): |
330 mm |
Incubator model: |
cooling incubator |
Interior volume: |
up to 50 l |
Depth outside (incubators,...): |
600 mm |
Depth inside (incubators,...): |
277 mm |
Lowest temperature (cooling): |
0 °C |
BINDER cooling incubator |
KB 23 |
Exterior dimensions |
|
Width (mm) |
435 |
Height (incl. feet) (mm) |
620 |
Depth (incl. door handle, I-panel and connection 73 mm) (mm) |
600 |
Wall clearance, rear (mm) |
100 |
Wall clearance, side (mm) |
100 |
Number of doors (ea.) |
1 |
Inner glass door(s) (ea.) |
1 |
Interior dimensions |
|
Width (mm) |
222 |
Height (mm) |
330 |
Depth (mm) |
277 |
Interior volume (l) |
20 |
Racks (number standard/max.) |
2 / 3 |
Load per rack (kg) |
10 |
Permitted total load (kg) |
25 |
Weight (empty) (kg) |
44 |
Temperature data |
|
Temperature range (°C) 1) |
0 - 100 |
Temperature variation at 5 °C (± K) at 25 °C (± K) at 40 °C (± K) |
0,7 0,3 0,3 |
Temperature fluctuation at 5 °C (± K) at 25 °C (± K) at 40 °C (± K) |
0,3 0,4 0,1 |
Recovery time after door was opened for 30 sec 2) at 5 °C (± K) at 40 °C (± K) |
5 2 |
Electrical data |
|
IP protection class acc. to EN 60529 |
IP 20 |
Voltage (±10 %) 50/60 Hz (V) 60 Hz (V) |
230 1 N ~ 115 1 N ~ |
Nominal power (kW) |
0,34 |
Energy consumption 3) at 37 °C (W) |
60 |
Noise level (dB (A)) |
47 |
1) Lower values are valid up to an ambient temperature of max. 25 °C.
2) To 98% of the set value
3) These values can be used for dimensioning air condition systems.
The useable interior height depends on the position of racks.
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.
Toller Kundenservice und schnelle Beantwortung aller Fragen. Wir benötigten eine komplette Laborausstattung für unseren neuen Standort. Das Team von MedSolut hat alles zu unserer Zufriedenheit geregelt.
Kunde
There are no reviews yet.