BINDER CO2 incubator CB 220, O2 control, gas-tight, divided glass panel
The BINDER CB 220 CO2 incubator with O2 control and gas-tight, divided glass screen is a highly sophisticated unit that has been specially developed to meet the requirements of modern laboratories. This incubator is ideal for the cultivation of microorganisms, insect and animal cultures as well as for various incubation and development processes. Thanks to its precise control and robust design, the CB 220 is a preferred choice for researchers and laboratory technicians who require reliable and reproducible results. Similar to the BINDER CO2 incubator CB 160, standard equipment, the CB 220 offers a variety of functions that make it an indispensable tool in laboratory work.
Technical data and functions
The BINDER CO2 incubator CB 220 is characterized by a variety of technical features that make it particularly efficient and user-friendly:
-
Incubator type: CO2 incubator
-
Incubator type: Incubator
-
Max. load: 11 - 50 kg
-
Internal volume: 210 liters
-
Maximum temperature: +60 °C
-
Internal dimensions: Width 560 mm, height 750 mm, depth 500 mm
-
External dimensions: Width 740 mm, height 1070 mm, depth 715 mm
-
Temperature range: 7 °C above room temperature to 60 °C
-
CO2 range: 0-20 % by volume
-
O2 range: 0.2 - 95 % by volume
-
Humidity: 90-95 % r.h.
-
Weight (empty): 121 kg
The CB 220 has a variety of functions that enable precise control and monitoring of the incubation conditions:
-
Easy-to-use controller: Simultaneous display of all important information
-
Electronic chart recorder: For the graphical display of process parameters
-
VENTAIR™ air jacket system: Available depending on model
-
Hot air sterilization at 180 °C: Complies with DIN 58947 standards
-
CO2 infrared absorption measuring system: Drift-free and precise
-
ANTI.PLENUM design: Prevents contamination-critical installations
-
Permadry™ system: Double tray humidification system with defined condensation location
-
Fault auto-diagnostic system: With visual and audible alarm
-
Ethernet interface: For the APT-COM™ DataControlSystem communication software
Certifications and standards
The BINDER CB 220 CO2 incubator meets important standards and certifications that underline its quality and reliability:
-
DIN 58947: Hot air sterilization at 180 °C in accordance with standards
-
BINDER test certificate: Guarantees compliance with the highest quality standards
Application examples
The CB 220 is versatile and suitable for a wide range of applications in research, medicine and laboratory work:
-
Cultivation of microorganisms: Ideal for cultivating and examining bacteria and fungi
-
Insect and animal cultures: Perfect for breeding and observing insects and small animals
-
Cell growth processes: Monitoring and analysis of cell behavior and growth
-
Hatching and development processes: Support in the development of embryos and other biological samples
FAQs
How precise is the temperature control of the CB 220?
The temperature control of the CB 220 is extremely precise, with a spatial temperature deviation of ±0.4 K at 37 °C and a temporal temperature deviation of ±0.1 K.
Can the CB 220 also be used for cultivating plant cells?
Yes, the CB 220 is also suitable for cultivating plant cells as it provides stable and controlled conditions for cell growth.
What safety features does the CB 220 offer?
The CB 220 has an electronic fault auto-diagnostic system with visual and audible alarm and a temperature selector monitor with visual and audible temperature alarm.
Conclusion
The BINDER CB 220 CO2 incubator with O2 control and gas-tight, split glass baffle is a sophisticated and versatile unit that is ideal for a wide range of applications in research and laboratory work. With its precise control functions and robust safety features, the CB 220 offers a reliable solution for the cultivation and analysis of biological samples. Similar to the BINDER CO2 Incubator C170-230V/120V, the CB 220 is an excellent choice for laboratories that place the highest demands on their equipment.
Load max.: |
11 - 50 kg |
Width outside (incubators,...): |
740 mm |
Width inside (incubators,...): |
560 mm |
Maximum temperature (heat): |
+ 60 °C |
Height outside (incubators,...): |
1070 mm |
Height inside (incubators,...): |
750 mm |
Incubator model: |
CO2 incubator |
Interior volume: |
201 - 300 l |
Cabinet type: |
incubator |
Depth outside (incubators,...): |
715 mm |
Depth inside (incubators,...): |
500 mm |
BINDER CO2 incubator |
CB 220 |
Exterior dimensions |
|
Width (mm) |
740 |
Height (incl. feet) (mm) |
1070 |
Depth (plus 54 mm for door handle and connection) (mm) |
715 |
Wall clearance side / rear (mm) |
50 / 100 |
Number of doors (ea.) |
1 |
Inner glass door(s) |
1 |
Interior dimensions |
|
Width (mm) |
560 |
Height (mm) |
750 |
Depth (mm) |
500 |
Interior volume (l) |
210 |
Stainless steel shelf (number standard/max.) |
3 / 8 |
Dimensions of shelf, width x depth (mm) |
555,5 x 444 |
Load per shelf (kg) |
10 |
Permitted total load (kg) |
30 |
Weight (empty) (kg) |
121 |
Temperature data |
|
Temperature range approx. 7 °C above ambient temperature to (°C) |
60 |
Temperature variation at 37 °C (± K) |
0,4 |
Temperature fluctuation (± K) |
0,1 |
Recovery time after door was opened for 30 sec. at 37 °C (min.) 1 |
5 |
Humidity data |
|
Humidity (±2 % r.h.) |
90-95 |
CO2 data |
|
CO2 range (Vol.-% CO2) |
0-20 |
Setting accuracy (Vol.-% CO2) |
0,1 |
Recovery time after door was opened for 30 sec. 1) at 5.0 vol. % CO2 (min.) |
5 |
CO2 measurement |
IR |
Connection hose nozzle for CO2 DN 6 for hose with internal diameter (mm) |
6 |
O2 data |
|
O2 range (Vol.-% O2) |
0,2 - 95 |
Setting accuracy (Vol.-% O2) |
0,1 |
Recovery time after door was opened for 30 sec. 1) at 1.0 vol. % O2 (min.) at 5.0 vol. % O2 (min.) |
18 18 |
O2 measurement |
ZrO2 |
Connection hose nozzle for O2 / N2 DN 6 for hose with internal diameter (mm) |
6 |
Electrical data |
|
Voltage (± 10%) 50/60 Hz (V) 60 Hz (V) |
230 115 |
Nominal power (kW) |
1,5 |
Energy consumption at 37 °C (W) 2) |
120 |
1) up to 98 % of the set value
2) These values can be used for dimensioning air condition systems.
All technical data is specified for unloaded units with standard equipment at an ambient temperature of 22 ± 3 °C / 71.6 ±5.4 °F and a power supply voltage fluctuation of ±10. The temperature data is determined in accordance to BINDER factory standard and DIN 12880, observing the recommended wall clearances of 10 % of the height, width and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.